Tilt-Up Catalog

SureBuilt
Concrete Forms & Accessories
Tilt-Up Catalog

PAGE 2
========================================================================

Safety Information

Read, understand and follow the information in this publication before using any SureBuilt tilt-up products and accessories. When in doubt
about the proper use or installation of any SureBuilt product, immediately contact the nearest SureBuilt branch for clarification.
SureBuilt products are intended for use by trained, qualified and experienced users only. Misuse or lack of supervision and/or inspection can
contribute to serious accidents or deaths. Any application other than those shown in this publication should be carefully tested and supervised
before use.
The user of SureBuilt products must evaluate the application, determine the safe working load and control all field conditions to prevent load in
excess of product(s) capacity. Safety factors shown in this publication are approximate minimum values. The data used to develop safe working
loads for products is a combination of actual testing and/or other industry sources. Do not exceed the recommended safe working loads.
Worn Parts
For safety, tilt-up products and accessories must be properly used and maintained. Products may be subject to wear, overloading, corrosion,
deformation, alteration and other factors that may affect performance. It is the responsibility of the user to schedule regular inspections and
remove worn and damaged parts from service.
Field Modification
Field welding can compromise product performance, alter load capacities, and create hazardous situations. Consult with a local welding supply
dealer to determine appropriate welding procedures. Do not weld any casting unless approved by a licensed metallurgical engineer. Since
SureBuilt can not control workmanship or site conditions, SureBuilt can not be responsible for any product alterations or field modifications.
Interchangeability
Tilt-up products manufactured and supplied by SureBuilt are designed as a system. When used properly, SureBuilt products have proven
to be among the best designed and safest in the industry. SureBuilt strongly discourages efforts to interchange products supplied by other
manufacturers because it may diminish performance and safety of the system.
Design Changes
SureBuilt reserves the right to change product designs, specifications, capacities and/or dimensions at any time and without prior notice.

Safety Factors
Safety factors established by the Occupational Safety and Health Administration (OSHA), Act Part 1910 and American National Standards
Institute (ANSI 10.9) are recommended. Contact SureBuilt Engineering for questions or concerns regarding unforeseen site conditions. Safety
factors should be adjusted when different or unusual conditions are known to exist.

Panel weight – The inserts must be positioned as instructed to obtain equal load.
Industry Recommendation
Angle Factor – The length of the sling and position of the inserts affect the load. Safety Factor* Intended Application
Angle in relation to concrete 90° 75° 60° 45° 30° 1.67 to 1 ** Wall Braces
Angle in relation to longitudinal axis 0° 15° 30° 45° 60° 2 to 1 Brace Inserts
Increase of force in sling 1 1.04 1.16 1.43 2.00 2 to 1 Lifting Inserts (single use)
3 to 1 Permanent panel connections
4 to 1 Panel handling (multiple lifts)
Impact Factor – The lifting and handling of tilt-up panels affect the load.
5 to 1 Lifting/Reusable Hardware
Mobile crane at site Force multiple of 1.5 to 1.7
* Minimum requirement.
Handling over uneven terrain Force multiple of 1.6 to 2.0
** Assumes ASD loads.
Extreme circumstances Force multiple of > 2.0
Adhesion Factor – The strength of adhesive forces depends on the shape and texture of the panel face, the surface on which the panel was placed,
and/or the presence of water on the surface. The proper application of bondbreaker and the removal of any excess water is assumed in all cases.
Special considerations – For panels with complicated shapes, especially panels which may create suction during erection, higher factors must be
considered. The resulting forces can be may times higher than the panel weight as represented by the following formula:
Panel Weight x Angle Factor x Impact Factor x Adhesion Factor*
Force = Number of Anchors
* The 2.5:1 safety factor already assumes 1.25 adhesion factor.

2 Call 708-493-9569 www.surebuilt-usa.com

PAGE 3
========================================================================

Table of Contents

Ring-Lift System …………………………………………………………………………………………….4

Ring Clutch ……………………………………………………………………………………………………6
Rigging Configurations ……………………………………………………………………………………7
SureLift (SL) Insert …………………………………………………………………………………………8
ProLift (PRO) Insert ………………………………………………………………………………………10

Straight Leg Erection Anchor ………………………………………………………………………….12
Lifting System ………………………………………………………………………………………………14
Strongbacks …………………………………………………………………………………………………16
Brace Insert ………………………………………………………………………………………………..18

Pipe Braces …………………………………………………………………………………………………22
Modular Braces ……………………………………………………………………………………………28
HGA Bracket ………………………………………………………………………………………………..31
Helical Ground Anchor …………………………………………………………………………………..32

Concrete Screw Anchor Bolt …………………………………………………………………………..34
Taper Bolt and Expander Nut ………………………………………………………………………….35
Panel Base Connector …………………………………………………………………………………..36

Slant Anchor ……………………………………………………………………………………………….37
SureGrip …………………………………………………………………………………………………….38
Edge Connector ……………………………………………………………………………………………39
Edge Form Brackets ……………………………………………………………………………………..40

Adhesives ……………………………………………………………………………………………………40
Profiles ………………………………………………………………………………………………………..41
Bar Support ………………………………………………………………………………………………….42
Patch Cap and Shims ……………………………………………………………………………………43

Slab Edge Protector ………………………………………………………………………………………43
FRP Truss ……………………………………………………………………………………………………44
Brace Spacing Bid Guidelines ………………………………………………………………………..46

Bracing Guidelines ………………………………………………………………………………………..47
Coatings and Finishes …………………………………………………………………………………..48
Warnings ……………………………………………………………………………………………………..49

Product specifications subject to change without notice.

Call 708-493-9569 www.surebuilt-usa.com 3

PAGE 4
========================================================================

Ring-Lift System

SureBuilt has combined the best in design and manufacturing, with extensive industry experience, to create an
effective, efficient and safe tilt-up system.

The Ring-Lift System is designed for tilt-up loads up to 22,000 lbs. System components are routinely sampled
and tested for specification conformance and product performance.
8 7 6 5 4 3 2 1
Ring Clutch D D
The Ring Clutch connects the tilt-up insert to crane
rigging and lifts the concrete panel from the casting
surface. The “ring” shape hooks securely onto the
C C
loop of the insert for lifting and handling.
The design of the Ring Clutch discharges the lateral
forces of angular lifting directly into the tilt-up panBel. B
Once lifted and braced in position, the Ring Clutch
can be safely released from the ground.
Ring Clutch
A A
Inserts 8 7 6 5 4 3 2 1
The SureLift (SL) Insert has double bend legs, non-
rusting plastic feet and a disposable void former
with locator antenna. The insert and rebar design
determine the lifting requirements.
The ProLift (PRO) Insert is another type of insert with
higher capacity. The non-rusting, star-shaped feet
can be removed and rotated to provide 1/4” height
adjustment.
SureLift (SL) Insert
ProLift (PRO) Insert
Brace Insert
8 7 6 5 4 3 2 1
The Brace Insert provides an attachment point for
D D
the Strongbacks and Pipe Braces used during tilt-up
lifting, handling and bracing.
C C
A Double Brace Insert is also available to accurately
position inserts for larger size panels, with greater
loads, requiring multiple Pipe Braces. B B
Inverted
Brace Insert
Brace In A se 8 rt 7 6 5 I P N IAPWN SERNO H RO PYTT OMR PHERLO EI :IEES SR H T PS TW H I DRIB YO EORI IT NO T ADI H N E WFUOOD FCSI F O U. NTU T R S GIROU M TEI RNABHS E T UEIT B IN IHO UWL PTEN IRLA SCTI CRTOO OTCTLM N OEEOPT NM RAA P NIAA NYSN E. YAD TOL U UE N NDR L LIA D M E EN OS SEC S S D N N FE ER S OO O: AC I AN TT T 4 O IC H H GM N S TE E U C A S OR R L A L R A AW W : L : R R E ± I I ± E : S S 0 D E E ±1. I R 0 N /1S S 3 A 3 °P P 2 I 1 W N E E “3 IC CC NI IH F F G E I I E ES D D F M I A N T IS E H RI : AL: WEIG HLTB:S T R PA I E 3 T R V L T : E : NO: SIZDE: SCALE: DWG NO: SHE1E T:OF1 D C D A H P A R P T E A R C E W O : K 2 N E V : D ED : : PHO8N4E0: S(7. 0285)T 4H9 3A-V9E5.6 9B E- LFLAWXO: O(1 D7,0 8IL) 4690310-49601 A

4 Call 708-493-9569 www.surebuilt-usa.com

PAGE 5
========================================================================

Insert Placement
The insert is designed and manufactured to create
an effective, efficient and safe tilt-up system. These
inserts are routinely sampled and tested for product
performance. Tests confirm these inserts meet or
exceed industry safety specifications.
Insert Placement (rebar not shown)
The insert legs and rebar design form the tilt-up
panel shear cone. This is an angle of approximately
Top of Panel
35° in relation to the longitudinal axis of the insert.
Attaching the Ring Clutch
The user must conduct a visual inspection to detect
any possible damage or defects in the Ring Clutch
before use. The ring-shape of the Ring Clutch hooks
onto the loop of the insert for lifting.

Move the handle to “open” the Ring Clutch ring,
position the Ring Clutch over the insert and move the
Attaching the Ring Clutch
handle to “close” the ring.
Engaging the Ring Clutch
Top of Panel
Position the handle of the Ring Clutch between the
rigging and the top of the panel. The handle should
be positioned against the concrete surface during
lifting and handling.
The chain attachment should pass through the bail
opening, then be connected to a line for a safe
ground release.

Preparing for Panel Lift
The user must conduct a visual inspection to detect
any possible damage or defects in the Ring Clutch.
Engaging the Ring Clutch
The user must verify the crane rigging, capacity and
positioning are adequate for the lifting sequence. Top of Panel
Angular lifting increase the forces must be taken into
account.

The handle should remain against the concrete
surface during lifting and handling. All nonessential
personnel should remain at a distance as a safety
precaution.

Emergency Lifting Plate may need to be used if
anchor has sunk or shifted when the panel was
Preparing for Panel Lift
poured.

Call 708-493-9569 www.surebuilt-usa.com 5

PAGE 6
========================================================================

Ring Clutch

The Ring Clutch connects the tilt-up insert to crane
rigging for lifting the concrete panel from the casting
surface. The “ring” shape hooks securely onto the
loop of the insert for lifting and handling.

The design of the Ring Clutch discharges the lateral
forces of angular lifting directly into the tilt-up panel.
Once lifted and braced in position, the Ring Clutch
can be safely released from the ground.

All erection calculations should be performed
under the direct supervision of and reviewed by a
Professional Engineer.

Ring Clutches must be maintained regularly. A
maintenance program is available.

Ring Clutch
Part No. Description SWL* B (in.) D (in.) E (in.) F (in.) X (in.)

SBRL22KP10T Ring Clutch 22,000 lbs 4.75 2.38 5.00 10.25 7.50
* Safe Working Load (SWL) based on 5:1 safety factor.

6 Call 708-493-9569 www.surebuilt-usa.com

PAGE 7
========================================================================

Rigging

Insert positions and rigging must be provided by an experienced tilt-up professional.

Call 708-493-9569 www.surebuilt-usa.com 7

[Text from diagrams]
Diagram labels (left to right, top to bottom):
1-2; 1-4; 1-8
2-2; 2-4; 2-4
4-2; 4-4; 2-8

PAGE 8
========================================================================

SureLift (SL) Insert

The SureLift Insert is designed for lifting tilt-up
panels. The insert develops high pull-out strength for
every panel thickness up to 12” (see table).

The integrated plastic former has antennae to identify
the insert location and lid to keep concrete out of the
lifting recess. The slide-on plastic feet, available for
+1/4”, +1/2” or +3/4” adjustment, keep the steel insert
feet away from the panel face to prevent corrosion.

Typical placement to prevent SL Insert from moving. Tie all
rebar so installation is secure.

Optional plastic feet are used for
positioning the SL insert on rigid
foam for insulated panels.

SureLift (SL) Insert with Plate (Insulated Panels)
Structural 2.5:1 SWL* 2:1 SWL*
Part No. Description
Thickness (Tension lbs) (Shear lbs)
SBRL22SLP5 SL Insert 5” wPlate 5” 9,400 13,160
SBRL22SLP512 SL Insert 5-1/2” wPlate 5-1/2” 9,900 13,960 SureLift Insert with Plate
* Safe Working Load (SWL) is based on testing in 3,000 psi concrete. (Insulated Panels)

SureLift (SL) Insert When the structural
Structural 2.5:1 SWL* 2:1 SWL* thickness of an insulated
Part No. Description
Thickness (Tension lbs) (Shear lbs) panel is less than 6”, a
SBRL22SL5 SL Insert 5” 5” 5,200 7,300 SureLift Insert with an
SBRL22SL6 SL Insert 6” 6” 10,450 14,800 integrated steel plate may
be needed. The plate
SBRL22SL634 SL Insert 6-3/4” 6-3/4” 10,450 14,800
and weld attachment
SBRL22SL7 SL Insert 7” 7” 13,500 19,000
compensate for the smaller
SBRL22SL714 SL Insert 7-1/4” 7-1/4” 13,500 19,000
height of the insert.
SBRL22SL712 SL Insert 7-1/2” 7-1/2” 13,500 19,000
SBRL22SL734 SL Insert 7-3/4” 7-3/4” 13,500 19,000
The inserts should always
SBRL22SL8 SL Insert 8” 8” 15,500 21,900 be positioned and tied to
SBRL22SL812 SL Insert 8-1/2” 8-1/2” 15,500 21,900 rebar so the placement
SBRL22SL9 SL Insert 9” 9” 18,350 22,000 remains secure.
SBRL22SL914 SL Insert 9-1/4” 9-1/4” 18,350 22,000
SBRL22SL934 SL Insert 9-3/4” 9-3/4” 18,350 22,000
SBRL22SL10 SL Insert 10” 10” 20,550 22,000
SBRL22SL11 SL Insert 11” 11” 22,000 22,000
SBRL22SL12 SL Insert 12” 12” 22,000 22,000
SBIF Insulation Foot — — —
* Safe Working Load (SWL) based on testing in 3,000 psi concrete.
8 Call 708-493-9569 www.surebuilt-usa.com

PAGE 9
========================================================================

Double SureLift (SL) Insert

The capacity of the SureLift Insert is increased by
using two inserts in combination. The two inserts,
joined with a steel Spacer Strap, develop an even
higher pull-out strength for every panel thickness up
to 12” (see table).

The Double Insert is properly positioned at 18” OC
with a Spacer Strap, then tied into the panel rebar.

Spreader Beam is used with
double inserts and two Lifting
Clutches for heavier panels. Spacer Strap (18” OC)

Double SureLift (SL) Insert* (18” OC) with Spacer Strap
Structural 2.5:1 SWL** 2:1 SWL**
Part No. Quantity? Description
Thickness (Tension lbs) (Shear lbs)
SBRL22SL6 Double SL Insert 6” 6” 20,900 29,550
SBRL22SL634 Double SL Insert 6-3/4” 6-3/4” 20,900 29,550
SBRL22SL7 Double SL Insert 7” 7” 26,900 35,000

SBRL22SL714 Double SL Insert 7-1/4” 7-1/4” 26,900 35,000
SBRL22SL712 Double SL Insert 7-1/2” 7-1/2” 26,900 35,000
SBRL22SL734 Double SL Insert 7-3/4” 7-3/4” 26,900 35,000

SBRL22SL8 Double SL Insert 8” 8” 30,950 35,000
SBRL22SL812 Double SL Insert 8-1/2” 8-1/2” 30,950 35,000

SBRL22SL9 Double SL Insert 9” 9” 35,000 35,000
SBRL22SL914 Double SL Insert 9-1/4” 9-1/4” 35,000 35,000
SBRL22SL934 Double SL Insert 9-3/4” 9-3/4” 35,000 35,000

SBRL22SL10 Double SL Insert 10” 10” 35,000 35,000
SBRL22SL11 Double SL Insert 11” 11” 35,000 35,000
SBRL22SL12 Double SL Insert 12” 12” 35,000 35,000

SBRL22SS18 Spacer Strap 18” OC — — —

* Double SureLift Insert is two inserts (18” OC) connected with Spacer Strap.
** Safe Working Load (SWL) based on testing in 3,000 psi concrete.

Call 708-493-9569 www.surebuilt-usa.com 9

PAGE 10
========================================================================

ProLift (PRO) Insert

The ProLift Insert is designed for lifting tilt-up panels.
The insert develops high pull-out strength with the
additional base crossbars.

The integrated plastic former has antennae to identify
the insert location and lid to keep concrete out of the
lifting recess. The star-shaped plastic feet, rotated for
+1/4”, +1/2” or +3/4” adjustment, keep the steel insert
feet away from the panel face to prevent corrosion.

Typical placement to prevent PRO Insert from
moving. Tie all rebar so installation is secure.

Optional plastic feet are used for
positioning the PRO insert on
rigid foam for insulated panels.

ProLift (PRO) Insert
Structural 2.5:1 SWL* 2:1 SWL*
Part No. Description
Thickness (Tension lbs) (Shear lbs)
SBRL22PRO512 PRO Insert 5-1/2” 5-1/2” 11,800 17,000
SBRL22PRO6 PRO Insert 6” 6” 14,000 17,500
SBRL22PRO634 PRO Insert 6-3/4” 6-3/4” 14,000 17,500

SBRL22PRO7 PRO Insert 7” 7” 17,350 22,000
SBRL22PRO714 PRO Insert 7-1/4” 7-1/4” 17,350 22,000
SBRL22PRO712 PRO Insert 7-1/2” 7-1/2” 17,350 22,000

SBRL22PRO734 PRO Insert 7-3/4” 7-3/4” 17,350 22,000
SBRL22PRO8 PRO Insert 8” 8” 19,000 22,000

SBRL22PRO812 PRO Insert 8-1/2” 8-1/2” 19,000 22,000
SBRL22PRO9 PRO Insert 9” 9” 22,000 22,000
SBRL22PRO914 PRO Insert 9-1/4” 9-1/4” 22,000 22,000

SBRL22PRO934 PRO Insert 9-3/4” 9-3/4” 22,000 22,000
SBRL22PRO10 PRO Insert 10” 10” 22,000 22,000

SBRL22PRO11 PRO Insert 11” 11” 22,000 22,000
SBRL22PRO12 PRO Insert 12” 12” 22,000 22,000
SBIF Insulation Foot — — —

* Safe Working Load (SWL) based on testing in 3,000 psi concrete.

10 Call 708-493-9569 www.surebuilt-usa.com

PAGE 11
========================================================================

Double ProLift (PRO) Insert

The capacity of the ProLift Insert is increased by
using two inserts in combination. The two inserts,
joined with a steel Spacer Strap, develop an even
higher pull-out strength for every panel thickness up
to 12” (see table).

The Double Insert is properly positioned at 18” OC
with a Spacer Strap, then tied into the panel rebar.

Spreader Beam is used with
double inserts and two Lifting
Clutches for heavier panels. Spacer Strap (18” OC)

Double ProLift (PRO) Insert* (18” OC) with Spacer Strap
Structural 2.5:1 SWL** 2:1 SWL**
Part No. Description
Thickness (Tension lbs) (Shear lbs)
SBRL22PRO6D Double PRO Insert 6” 6” 22,000 30,000
SBRL22PRO634D Double PRO Insert 6-3/4” 6-3/4” 22,000 30,000
SBRL22PRO7D Double PRO Insert 7” 7” 27,000 35,000

SBRL22PRO714D Double PRO Insert 7-1/4” 7-1/4” 28,000 35,000
SBRL22PRO712D Double PRO Insert 7-1/2” 7-1/2” 28,000 35,000
SBRL22PRO734D Double PRO Insert 7-3/4” 7-3/4” 28,000 35,000

SBRL22PRO8D Double PRO Insert 8” 8” 32,000 35,000
SBRL22PRO812D Double PRO Insert 8-1/2” 8-1/2” 32,000 35,000

SBRL22PRO9D Double PRO Insert 9” 9” 35,000 35,000
SBRL22PRO914D Double PRO Insert 9-1/4” 9-1/4” 35,000 35,000
SBRL22PRO934D Double PRO Insert 9-3/4” 9-3/4” 35,000 35,000

SBRL22PRO10D Double PRO Insert 10” 10” 35,000 35,000
SBRL22PRO11D Double PRO Insert 11” 11” 35,000 35,000
SBRL22PRO12D Double PRO Insert 12” 12” 35,000 35,000

SBRL22SS18 Spacer Strap 18” OC — — —

* Double SureLift Insert is two inserts (18” OC) connected with Spacer Strap.
** Safe Working Load (SWL) based on testing in 3,000 psi concrete.

Call 708-493-9569 www.surebuilt-usa.com 11

PAGE 12
========================================================================

8 7 6 5 4 3 2 1
D D

Drop-Forged Foot Erection Anchor

The Drop-Forged Foot Erection Anchor has a specially
designed shape for precast concrete edge lifts that
make it easier to install without reducCing the load C
capacity.

The protrusions or “ears” at the top of the anchor
restrict rotation during lifting, protecting the concrete
from spalling. The body is shaped to allow for full panel
reinforcement, providing support during lifting. The
integrated foot eliminates the need for an additional
shear bar, simplifying anchor installation.

During panel rotation, the sling angle should be
perpendicular to the surface. The anchors will not be
bearing the full weight of the panel.
B B
Once the panel has been rotated to vertical, the
tension is initiated. During this phase, the drop forged
foot at the bottom develops a tension load.

Drop-Forged Foot Erection Anchor*
Part No. Anchor Clutch Width Length Plate Tension*

SBDFFEA5TG 5 Ton 4-5 Ton 3-1/2” 10” 3”x4” 11,000 lbs
SBDFFEA10TG 10 Ton 8-10 Ton 4-1/2” 12-1/2” 3-1/4”x4” 22,000 lbs

• Panels less than 6” thick require 5T Drop-Forged Foot Erection Anchor and 5T Ring Clutches.
A A

TOL
U
E
N
D
R
L
I
A
M
E
N
S
E
C
S
N
E
S
O
:
I
T
O
H
N
E
S
R
A
W
R
I
E
S E
I N
S P
IN
EC
C
I
H
F
E
IE
S
D
MATERIAL: TITLE: D
D
A
R
T
A
E
W
:
N:
Part No. Dispos D ab es le c r F i o p8 r ti m on er 7 I P N I AP W N SE RN O H R O P Y TT OMR PHE RL O E I :I EE S SR H T P S T W H I D R IB Y O E O R I I T N O T A D I H N E WFU OO D F CSI F O U . N TU T R S G IRO U M T EI R N A B H S E T U EI T B I N IHO WU L PTEN IRL A SC IT C RT OO O T CT LM N OE E OP T NM RA A P N I A A N YS N E . Y A D U C NL D E O S 6 S D l N F E R O O A u C A N T T I C H G M S T E U C A O R L t A L R A W : L : R E ± c I ± : S 0 D E 1 ± . R 0 / 1 S 3 A 3 h ° P 2 1 W E ” 3 I C N IF G IE I D D FINISH: 5 WEIG H L T B : S R PA E R V T : NO: SIZ D E: 4 SCALE: DWG NO: SHE 1 E T: OF 1 3 C A H PP E R C O KE V D ED : : PHO 8 N 4 E 0 : S ( 2 7 . 0 2 8 5 ) T 4 H 9 3 A – V 9 E 5 . 6 9 B E – L F L A W X O : O ( D 7 , 0 8 IL ) 4 6 9 0 3 1 1 0 – 4 9601
SBRLDF5T Disposable Former 5T (Orange) 4-5T
SBRLDF8T SB Disposable Former 8T (Blue) 8-10T
12 Call 708-493-9569 www.surebuilt-usa.com

PAGE 13
========================================================================

Drop Forged Foot Erection Anchor*
Capacity Clutch ID Tension with
Panel Thickness** Shear***
(tons) marking Tension Bar*****
5T 4-5T 5” 3,450 lbs 8,000 lbs
5T 4-5T 5-1/2” 4,200 lbs 8,000 lbs
10T 22 kip 6” 4,600 lbs 22,000 lbs

10T 22 kip 6-1/2” 5,000 lbs 22,000 lbs
10T 22 kip 7” 5,400 lbs 22,000 lbs
10T 22 kip 7-1/2” 5,684 lbs 22,000 lbs

10T 22 kip 8” 5,958 lbs 22,000 lbs
10T 22 kip 9” 6,589 lbs 22,000 lbs
10T 22 kip 10” 7,041 lbs 22,000 lbs

10T 22 kip 11” 7,448 lbs 22,000 lbs
10T 22 kip 12” 7,853 lbs 22,000 lbs

* Minimum distance to panel corners is 24”, minimum distance between inserts is 24”.
** Anchor must be centered within panel thickness, panels less than 6” thick require 4T anchor.
*** 2.5:1 safety factor in 3,000 psi concrete.
**** 2:1 safety factor in 3,000 psi concrete.
***** The 4T requires minimum 54” #5 Tension Bar, 10T requires minimum 66” #6 Tension Bar.

8 7 6 5 4 3 2 1

Tension Bar (shown with anchor) D D

Part No. Description Rebar Length*
SBTB4T Tension Bar 4-5T #5 54”
SBTB8T Tension Bar 8-10T #6 66”

* Minimum total length, including bend, to develop full strength of anchor.
C C

B B

Call 708-493-9569 www.surebuilt-usa.com 13

A A

8 7 I P NPA IW N SE RN O H R O P YTT OMR PHE RLO E I :IEES SR H T P S TW H I DRIB Y O E OR I IT N O T AD I H N E WFUOOD F CSI F O U. NTU T R S GIROU M ET I RN ABH S E T UEIT B I N IHO WU L TPEN IRLA SCIT C RT OO O TCT LM N OE EOPT NM RAA P NI AA NYSN E. YA D TOL U UE N ND R L LI A D M E EN O S SE C 6 S S D N N F E ER S O O O: A C I AN T T TO IC H H G M N S T E E U C A S O R R L A L R A AW W : L : R R E ± I I ± E : S S 0 D E E 1± . I R 0 N /1S S 3 A 3 °P P 2 I 1 W N E E “3 I C CC N I IH F F G E I I E ES D D F M I A N T IS E H RI : AL: 5 WEIG H L T B : S T R PA I E T R V L T : E : NO: SIZDE: 4 SCALE: DWG NO: SHE1E T:OF13 D D C A H P A R P T E A R C E W O : K N E V : D ED : : PHO8N4E0: S( 2 7. 0285)T 4H9 3A-V9E5.6 9B E- LFLAWXO: O(D7,0 8IL) 469031 1 0-49601

PAGE 14
========================================================================

Lifting System

The lifting system consists of two inserts, two Ring Clutches and a
Spreader Beam with two 10 ton shackles.

To develop the safe working load, inserts must be properly
positioned within the panel dimension. Single inserts must be
accurately spaced 18” on-center or a double insert must be the
used. Improper positioning or inaccurate spacing will affect and
reduce the lifting capacity.

The Double Insert (SL or PRO) is a fixed position assembly that
simplifies the panel installation and matches the Spreader Beam Spreader Beam is used with
spacing. double inserts and two Ring
Clutches for heavier panels.

Spreader Beam with Twin Shackles
The Spreader Beam is designed with two 10 ton shackles and
must be used with two ground release Ring Clutches. This will
eliminate many of the rigging challenges for very large or heavy
tilt-up panels.

The large center hole in the Spreader Beam will accept the many
different sizes of shackles used by tilt-up panel erectors.

Double Insert Spreader Beam
Part No. Description SWL*

SBDISB18 Double Insert Spreader Beam 35,000 lbs
18” shackle spacing
* Safe Working Load (SWL) based on 5:1 safety factor.
Double Insert Spreader Beam

14 Call 708-493-9569 www.surebuilt-usa.com

PAGE 15
========================================================================

Emergency Lifting Plate

The Emergency Lift Plate is designed for situations when the
original insert is improperly located or unusable. The plate is
attached to the tilt-up panel using Concrete Screw Anchor Bolts
3/4”x6” (recommended) or equivalent. Refer to manufacturer
instructions and load chart for proper anchor installation and
capacity.

The Emergency Lift Plate should be installed over the original
insert location or in alternate position designated by an
Emergency Lifting Plate
experienced tilt-up professional. If uncertain about the location,
contact the lift/brace engineer for further recommendations.
Always be certain the Emergency Lift Plate is aligned with crane
rigging cables. Plate connects to rigging with a 10 ton shackle.
The Emergency Lift Plate has a maximum safe working load
(SWL) of 22,000 lbs. (at 5:1 safety factor) and should never be
used in excess of that capacity.

When drilling holes for anchors, be careful not to inadvertently
damage structural rebar in the tilt-up panel. Only the Engineer
of Record (EOR) can approve deviations in the rebar design or
integrity. Contact the lift/brace engineer if additional reinforcing or
another configuration is needed for lifting purposes.

Emergency Lifting Plate
Part No. Description SWL*

SBELP Emergency Lifting Plate 12”x12” 22,000 lbs
* Safe Working Load (SWL) based on 5:1 safety factor. Emergency Lift Plate

with recommended
Concrete Screw Anchor Bolts
3/4” X 6”
SWL is 6,845 lbs / bolt
(2:1 safety factor)
Warning:
1. Concrete must have a minimum of 3,000 psi compressive strength.
2. Do not use the Concrete Screw Anchor Bolts in tilt-up panels thinner than 7”.
3. Edge distance should be a minimum of 12” to center of holes.
4. Do not reuse Concrete Screw Anchor Bolts.

Installation:
1. Drill holes at 90 degree angle to the panel surface using a 3/4” diameter carbide-tipped drill bit.
2. Drill a minimum of 5-3/4” deep for 6” anchor into the panel. Use the Emergency Lift Plate as a template.
3. Clean the drilled holes with compressed air or blow-out bulb.
4. Only use new Anchors with clean and undamaged threads.
5. Place Emergency Lift Plate over the holes and position Anchors.
6. Securely tighten the anchor using a 3/4” impact wrench to a minimum of 100 ft-lbs torque.
7. Use 3/4” F436 Structural Washer where needed.

Call 708-493-9569 www.surebuilt-usa.com 15

PAGE 16
========================================================================

Strongback

Strongbacks consist of back-to-back steel channels that are
spliced together with butt plates and grade 8, 3/4″ bolts torqued to
140 ft*lb to create the required length.

Strongbacks are used to reinforce critical areas of panels during
erection. Assembled strongbacks provide an open channel over
the entire length for bolting to panel inserts.

Panels with door and window openings may require strongbacks
Strongbacks can be bolted to
for temporary support during erection. As a guideline, when any
create different lengths.
concrete dimension is less than 2 feet wide or any panel thickness
is less than 7”, strongbacks are recommended.
Strongbacks can be placed near or over panel openings to
prevent “hinge” cracking during lifting. The panel engineering
company must advise on inserts, spacing and waler length.
Strongbacks are temporarily bolted to each insert with a coil rod,
washer and nut. The coil rod is placed between the back-to-back
channels with the washer bearing on the waler. When bolted the
strongback reinforces the panel for handling.

Butt Plate Waler used as strongback
Butt Plate Waler/Strongback
with Single Insert, Flat Washer and
Part No. Description Weight
Strongback Bolt/Nut.
SBBPW85 Butt Plate Waler 8”x5’ 115 lbs
SBBPW810 Butt Plate Waler 8”x10’ 230 lbs
SBBPW125 Butt Plate Waler 12”x5’ 250 lbs 12” spacing
SBBPW1210 Butt Plate Waler 12”x10’ 500 lbs
SBSB342 3/4”x2” Speed Bolt –
SBSN34 3/4” Speed Nut –
SBFW34661316 Flat Washer 3/4”x6”x6” 5

SBSBA112 18” Strongback Angle, holes at 12” OC 20
SBCR3416 3/4”x16” Coil Rod –
Butt Plate Waler used as strongback
SBCN34HH 3/4” Coil Nut Heavy Hex 0.4
with Double Insert, Strongback Angle
Moment capacity for 8” = 34.6 kip-ft @ 1.67:1 safety factor. and Strongback Bolts/Nuts.
Moment capacity for 12” = 91.9 kip-ft @ 1.67:1 safety factor.
8” Strongbacks use 3/4”x2” Speed Bolt
12” Strongbacks use 1”x2” Speed Bolt

16 Call 708-493-9569 www.surebuilt-usa.com

PAGE 17
========================================================================

Strongback Inserts

The Strongback Angle is used to fasten the Butt Plate Strongback
to the Double Insert and support the panel during lifting.

Strongback Insert with Plug* (Bolt sold separately)
Part No. Description SWL**

SBSBI345 Strongback Insert 3/4”x5” wPlug 7,200 lbs
SBSBI346 Strongback Insert 3/4”x6” wPlug 9,600 lbs
Strongback Angle
SBSBI34612 Strongback Insert 3/4”x6-1/2” wPlug 9,900 lbs
SBSBI34714 Strongback Insert 3/4”x7-1/4” wPlug 10,200 lbs
SBSBI348 Strongback Insert 3/4”x8” wPlug 11,600 lbs

SBSBI34812 Strongback Insert 3/4”x8-1/2” wPlug 11,600 lbs
SBSBI34914 Strongback Insert 3/4”x9-1/4” wPlug 11,600 lbs
SBSBI3410 Strongback Insert 3/4”x10” wPlug 11,600 lbs

SBSBI341114 Strongback Insert 3/4”x11-1/4” wPlug 11,600 lbs
SBSBI3412 Strongback Insert 3/4”x12” wPlug 11,600 lbs
Strongback Insert
* Distance from edge is minimum 12” or loads must be reduced.
** Safe Working Load (SWL) based on 2:1 safety factor.

Double Strongback Insert (12” OC) with Spacer Strap
Part No. Description SWL**
SBDSBI345 Double Insert 3/4”x5” wSpacer 12,960 lbs

SBDSBI346 Double Insert 3/4”x6” wSpacer 17,280 lbs
SBDSBI34612 Double Insert 3/4”x6-1/2” wSpacer 17,820 lbs

SBDSBI34714 Double Insert 3/4”x7-1/4” wPlug 18,360 lbs
SBDSBI348 Double Insert 3/4”x8” wSpacer 20,880 lbs
SBDSBI34812 Double Insert 3/4”x8-1/2” wSpacer 20,880 lbs Double Strongback Insert (12” OC)
with Spacer Strap
SBDSBI34914 Double Insert 3/4”x9-1/4” wSpacer 20,880 lbs
SBDSBI3410 Double Insert 3/4”x10” wSpacer 20,880 lbs

SBDSBI341114 Double Insert 3/4”x11-1/4” wSpacer 20,880 lbs
SBDSBII3412 Double Insert 3/4”x12” wSpacer 20,880 lbs
SBDSBISS12 Spacer Strap 12” OC —

* Distance from edge must be a minimum 12” or load is reduced.
** Safe Working Load (SWL) based on 2:1 safety factor.

Spacer Strap (12” OC)

Call 708-493-9569 www.surebuilt-usa.com 17

PAGE 18
========================================================================

Brace Insert

The Brace Insert has wire legs, welded to a coil insert, with a disposable plastic
plug. The wire legs have plastic feet to prevent corrosion at the concrete face.
The plastic plug has antennae to locate the insert after concrete placement. The
number and location of Brace Inserts will vary based on the dimensions of each
tilt-up panel. Other sizes are available on request.

When the disposable plastic plug is removed from the tilt-up panel the coil insert
is exposed, providing the anchor point for subsequent bracing. Note that Brace
Insert and Double Brace Insert SWLs are based on 55o Brace angle.

Brace Insert with Plug* (Bolt sold separately)

Part No. Description SWL**
SBBI345 Brace Insert 3/4”x5” wPlug 7,200 lbs
SBBI346 Brace Insert 3/4”x6” wPlug 9,600 lbs

SBBI34612 Brace Insert 3/4”x6-1/2” wPlug 9,900 lbs
SBBI34714 Brace Insert 3/4”x7-1/4” wPlug 10,200 lbs

SBBI348 Brace Insert 3/4”x8” wPlug 11,600 lbs
SBBI34812 Brace Insert 3/4”x8-1/2” wPlug 11,600 lbs
SBBI34914 Brace Insert 3/4”x9-1/4” wPlug 11,600 lbs

SBBI3410 Brace Insert 3/4”x10” wPlug 11,600 lbs
SBBI341114 Brace Insert 3/4”x11-1/4” wPlug 11,600 lbs

SBBI3412 Brace Insert 3/4”x12” wPlug 11,600 lbs
SBCB344 Coil Bolt 3/4”x4” —
* Distance from edge must be minimum 12” or load is reduced.
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi.
8 7 6 5 4 3 2 1

D D
Inverted Brace Insert

The Inverted Brace Insert is designed for tilt-up panels where the
anchor point for bracing is located on the bottom side of the concrete
C C
placement. Other sizes are available on request.
Inverted Brace Insert with Plug* (Bolt sold separately)

Part No. Description SWL**
B B
SBIBI343 Inverted Brace Insert 3/4”x3” wPlug 3,900 lbs
SBIBI346 Inverted Brace Insert 3/4”x6” wPlug 9,900 lbs
SBCB344 Coil Bolt 3/4”x4” —

* Distance from edge must be minimum 12” or load is reduced.
** Safe Working Load (SWL) based on 2:1 safe A ty fa 8 ctor @ 3,00 7 0 psi. 6 5 I P NPA IW N SE RN O H R O P YTT OMR PHE RLE OI :IEES SR H T P S TW H I DRIB Y O E OR I IT N O T AD I H N E WFUOOD F CSI F O U. NTU T R S GIROU M ET I RN ABH S E T UEIT B I N IHO UWL TPEN IRLA SC TI C RT OO O TCT LM N OE EOPT NM RAA P NI AA NYSN E. YA D TOL U U E N ND R L LI A D M E E N O S SE C S S D N N F E ER S O O O : A C I AN T T T 4 O IC H H G M N S T E E U C A S O R R L A L R A AW W : L : R R E ± I I ± E : S S 0 D E E 1± . I R 0 N /1S S 3 A 3 °P P 2 I 1 W N E E “3 I C CC N I IH F F G E I I E ES D D M FI A N T IS E H RI : AL: WEIG H L T B : S T R PA I E 3 T R V L T : E : NO: SIZDE: SCALE: DWG NO: SHE1E T:OF 1 D D C A H P A R P T E A R C E W O : K 2 N E V : D ED : : PHO 8 N 4 E 0 : S (7 . 0 2 8 5 ) T 4 H 9 3 A – V 9 E 5 . 6 9 B E – L F L A W X O : O ( 1 D 7 , 0 8 IL ) 4 6 9 0 3 10 – 4 9601 A

18 Call 708-493-9569 www.surebuilt-usa.com

PAGE 19
========================================================================

Double Brace Insert

The Double Brace Insert (10” OC) has wire legs, welded to a coil
insert with disposable plastic plugs, and Spacer Strap. The wire legs
have plastic feet to prevent corrosion at the concrete face. The plastic
plugs have antennae to locate the inserts after concrete placement.
The Spacer Strap keeps the inserts properly positioned. The number
and location will vary based on the dimensions of each panel.

When the disposable plugs are removed from the panel, the coil
inserts are exposed, providing the bolt locations for subsequent
bracing.

Double Brace Insert with Spacer Strap Double Brace Insert (10” OC)
with Spacer Strap
Part No. Description SWL**
SBDBI345 Double Brace Insert 3/4”x5” 12,960 lbs
SBDBI346 Double Brace Insert 3/4”x6” 17,280 lbs

SBDBI34612 Double Brace Insert 3/4”x6-1/2” 17,820 lbs
SBDBI34714 Double Brace Insert 3/4”x7-1/4” 18,360 lbs

SBDBI348 Double Brace Insert 3/4”x8” 20,880 lbs
SBDBI34812 Double Brace Insert 3/4”x8-1/2” 20,880 lbs
SBDBI34914 Double Brace Insert 3/4”x9-1/4” 20,880 lbs Spacer Strap (10” OC)

SBDBI3410 Double Brace Insert 3/4”x10” 20,880 lbs
SBDBI341114 Double Brace Insert 3/4”x11-1/4” 20,880 lbs

SBDBI3412 Double Brace Insert 3/4”x12” 20,880 lbs
SBDBISS10 Spacer Strap 10” OC —
SBCB344 Coil Bolt 3/4”x4” —

* Distance from edge must be minimum 12” or load is reduced.
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi.

Double Inverted Brace Insert

The Double Inverted Brace Insert (10” OC) is designed for panels
where the anchor points for bracing are located on the bottom side of
the concrete placement. Other sizes are available on request.

Double Inverted Brace Insert with Spacer Strap
Part No. Description SWL**
SBDIBI343 Double Inv Brace Insert 3/4”x3” 7,800 lbs

SBDIBI346 Double Inv Brace Insert 3/4”x6” 19,800 lbs
SBCB344 Coil Bolt 3/4”x4” — Double Inverted Brace Insert
(10” OC) with Spacer Strap
* Distance from edge must be minimum 12” or load is reduced.
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi.

Call 708-493-9569 www.surebuilt-usa.com 19

PAGE 20
========================================================================

Brace Bolt Insert

The insert is unique because the bolt is an integral part of the assembly.
The insert has wire legs for the slab thickness, plastic feet to prevent
corrosion at the concrete surface, a welded coil insert, a 3/4” bolt with
protective sleeve, and a disposable locator cap. When the disposable
locator cap is removed, the 3/4” bolt is exposed, providing the anchor
point for subsequent bracing.

Brace Bolt Insert with Flange Bolt and Cap
Part No. Description SWL**
SBBBI345 Brace Bolt Insert 3/4”x5” 7,200 lbs

SBBBI346 Brace Bolt Insert 3/4”x6” 9,600 lbs
SBBBI34612 Brace Bolt Insert 3/4”x6-1/2” 9,900 lbs

SBBBI34714 Brace Bolt Insert 3/4”x7-1/4” 10,200 lbs
SBBBI348 Brace Bolt Insert 3/4”x8” 11,600 lbs
SBBBI34812 Brace Bolt Insert 3/4”x8-1/2” 11,600 lbs

SBBBI34914 Brace Bolt Insert 3/4”x9-1/4” 11,600 lbs
SBBBI3410 Brace Bolt Insert 3/4”x10” 11,600 lbs
SBBBI341114 Brace Bolt Insert 3/4”x11-1/4” 11,600 lbs

SBBBI3412 Brace Bolt Insert 3/4”x12” 11,600 lbs
* Distance from edge is minimum 12” or loads must be reduced.
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi.

Inverted Brace Bolt Insert wFlange Bolt & Cap

The Inverted Brace Bolt Insert is designed for panels where the anchor
point for bracing is located on the bottom side of the panel.

Inverted Brace Bolt Insert* with Flange Bolt and Cap

Part No. Description SWL**
SBIBBI343 Inverted Brace Bolt Insert 3/4”x3” 3,900 lbs

SBIBBI346 Inverted Brace Bolt Insert 3/4”x6” 9,900 lbs
* Minimum distance from edge is 12” or loads must be reduced.
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi.

* U.S. Patent Pending

20 Call 708-493-9569 www.surebuilt-usa.com

PAGE 21
========================================================================

Double Brace Bolt Insert*

The Double Brace Bolt Insert (10” OC) has wire legs, welded to two
coil inserts, with a 3/4” bolts and plastic caps. The plastic caps have
antennae to locate the inserts after concrete placement. The number
and location of Double Brace Bolt Inserts will vary based on the panel
design. Other insert sizes are available on request.

When the disposable plastic caps are located and removed from
the panel, the coil inserts and 3/4” bolts are exposed, providing the
anchor points for subsequent bracing.

Double Brace Bolt Insert (10” OC)
Double Brace Bolt Insert* with Spacer Strap
with Spacer Strap
Part No. Description SWL**
SBDBBI345 Double Brace Bolt Insert 3/4”x5” 12,960 lbs
SBDBBI346 Double Brace Bolt Insert 3/4”x6” 17,280 lbs
SBDBBI34612 Double Brace Bolt Insert 3/4”x6-1/2” 17,820 lbs
SBDBBI34714 Double Brace Bolt Insert 3/4”x7-1/4” 18,360 lbs

SBDBBI348 Double Brace Bolt Insert 3/4”x8” 20,880 lbs
SBDBBI34812 Double Brace Bolt Insert 3/4”x8-1/2” 20,880 lbs
SBDBBI34914 Double Brace Bolt Insert 3/4”x9-1/4” 20,880 lbs

SBDBBI3410 Double Brace Bolt Insert 3/4”x10” 20,880 lbs
SBDBBI341114 Double Brace Bolt Insert 3/4”x11-1/4” 20,880 lbs

SBDBBI3412 Double Brace Bolt Insert 3/4”x12” 20,880 lbs
* Distance from edge is minimum 12” or loads must be reduced.
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi.

Double Inverted Brace Bolt Insert*

The Double Inverted Brace Bolt Insert (10” OC) is designed for panels
where the anchor points for bracing are located on the bottom side of
the concrete placement. Other sizes are available on request.

Double Inverted Brace Bolt Insert* with Spacer Strap
Part No. Description SWL**

SBDIBBI343 Double Inv Brace Bolt Insert 3/4”x3” 7,800 lbs
SBDIBBI346 Double Inv Brace Bolt Insert 3/4”x6” 19,800 lbs

* Minimum distance from edge is 12” or loads must be reduced. Double Inverted Brace Bolt Insert
** Safe Working Load (SWL) based on 2:1 safety factor @ 3,000 psi. (10” OC) with Spacer Strap

* U.S. Patent Pending

Call 708-493-9569 www.surebuilt-usa.com 21

PAGE 22
========================================================================

Pipe Braces

Adjustable Pipe Braces have a telescoping pipe for rough dimension, 6” threaded rod for adjustment and
connecting shoes for anchoring. There are three sizes of Adjustable Pipe Brace, ranging from 7’-6” to 40’-0”.

Pipe Braces have a fixed length, 18” threaded rod for adjustment and connecting shoes for anchoring. There
are four sizes, including optional extension lengths, ranging from 16’-6” to 32’-3”.

Heavy-Duty Pipe Braces have a larger diameter pipe for greater capacity, 18” threaded rod for adjustment
and connecting shoes anchoring. There are six sizes, including extensions, ranging from 31’-9” to 53’-3”.
(refer to the table for additional information on all braces).

Pipe Braces
Ultimate Brace Load*
Length Weight
Part No. Description w/o Knee Bracing
(lbs)
Min Max Maximum
Adjustable Pipe Brace
SBUP0 Adjustable Pipe Brace 5’-0” 8’-0” 9,750 lbs 60.0
SBUP1 Adjustable Pipe Brace 7’-6” 14’-0” 9,750 / 6,600 lbs 95.0
SBUP4 Adjustable Pipe Brace 14’-0” 23’-6” 9,750 / 3,200 lbs 130.0

SBUP5 Adjustable Pipe Brace 22’-6” 39’-0” 8,063 / not recommended 208.0
SBUP11A Adjustable Pipe Brace 25’-6” 40’-0” 13,500 / 8,250 lbs 500.0
Pipe Brace (4” diameter)

SBPB417 17’-0” Fixed Pipe Brace 16’-6” 17’-6” 9,750 lbs 105.0
SBPB422 22’-0” Fixed Pipe Brace 21’-0” 22’-2” 9,750 lbs 136.0

SBPB427 22’-0” Fixed Brace w/ 5’ Ext 26’-1” 27’-3” 7,200 lbs 188.0
SBPB432 22’-0” Fixed Brace w/ 10’ Ext 31’-1” 32’-3” 5,400 lbs 224.0
SBPBE45 5’ Extension 5’-0” 5’-0” – 23.0

SBPBE410 10’ Extension 10’-0” 10’-0” – 46.0
SBPB4COUPLER 4” Coupler – – – 28.0
Heavy-Duty Pipe Brace (5-1/2” diameter)

SBPB51232 32’-0” Fixed Brace 31’-9” 33’-3” 13,500 lbs 295.0
SBPB51232LHRH18 HD Pipe Brace w/ 18” Extensions 31’-9” 34’-9” 13,500 lbs 295.0

SBPB51237 32’-0” Fixed Brace w/ 5’ Ext 36’-9” 38’-3” 12,000 lbs 360.0
SBPB51242 32’-0” Fixed Brace w/ 10’ Ext 41’-9” 43’-3” 8,040 lbs 400.0
SBPB51252 32’-0” Fixed Brace w/ 20’ Ext 51’-9” 53’-3” 5,775 lbs 520.0

SBPB512EXT5 5’ Extension 5’-0” 5’-0” 39.0
SBPB512EXT10 10’ Extension 10’-0” 10’-0” 78.0

SBPB512COUPLER 5-1/2” Coupler – – 32.5
* Ultimate Brace Load based on test reports and calculations.

See Brace Spacing Bid Chart on pages 44-45

22 Call 708-493-9569 www.surebuilt-usa.com

PAGE 23
========================================================================

Diagram labels and dimensions:
Adjustable Pipe Braces
SBUP11A: 25′-6″ TO 40′-0″
SBUP5: 22′-6″ TO 39′-0″
SBUP4: 14′-0″ TO 23′-6″
SBUP1: 7′-6″ TO 14′-0″
SBUP0: 5′-0″ TO 8′-0″
Fixed Pipe Braces (4″ diameter)
SBPB432: 31′-3″ TO 32′-9″
SBPB427: 26′-3″ TO 27′-9″
SBPB422: 21′-3″ TO 22′-9″
Heavy-Duty Fixed Pipe Braces (5-1/2″ diameter)
SBPB51252: 51′-9″ TO 53′-3″
SBPB51242: 41′-9″ TO 43′-3″
SBPB51237: 36′-9″ TO 38′-3″
SBPB51232: 31′-9″ TO 33′-3″

Call 708-493-9569
www.surebuilt-usa.com

PAGE 24
========================================================================

Adjustable Pipe Brace (SBUP1)
Ultimate Brace Load*
D V X L
w/o Knee Bracing
9’-9” 6’-6” 3’-9” 7’-6” 9,750 lbs
10’-5” 6’-11” 4’-0” 8’-0” 9,750 lbs
11’-8” 7’-9” 4’-6” 9’-0” 9,750 lbs
14’-3” 9’-6” 5’-5” 11’-0” 9,750 lbs

15’-7” 10’-5” 6’-0” 12’-0” 8,175 lbs
18’-2” 12’-1” 7’-0” 14’-0” 6,600 lbs

* Ultimate Brace Load based on test reports.
** Knee bracing requires knee, lateral and end bracing to obtain the loads indicated.
*** Range for 45-60 degree angle.
Note: Pipe Braces should always be inspected for unusual wear or damage after each use. Any Pipe Brace
with missing parts, dents or kinks, indications of heating or other damage, should not be used until repaired.

24 Call 708-493-9569 www.surebuilt-usa.com

[Text from diagrams]
Diagram labels:
MIN. FLOOR THICKNESS 5″
L = 0.770 x D
1/2 x L
TILTWALL BRACE
KNEE BRACE
90°
MAX.-MIN. 60°-45°
TILTWALL PANEL
V = 0.667 x D
D = HEIGHT OF PANEL ABOVE FINISHED FLOOR
H = PANEL HEIGHT
G
PANEL BELOW FINISHED FLOOR
USE SHIMS TO LEVEL PANEL
X = 0.385 OF D
V = MINIMUM 2′ ABOVE CENTER OF GRAVITY

PAGE 25
========================================================================

Adjustable Pipe Brace (SBUP4)
Ultimate Brace Load* Ultimate Brace Load*
D V X L
w/o Knee Bracing with Knee Bracing**
19’-6” 13’-0” 7’-6” 15’-0” 9,750 lbs 9,750 lbs
20’-4” 13’-9” 7’-11” 15’-10” 9,750 lbs 9,750 lbs
21’-8” 14’-5” 8’-4” 16’-8” 9,750 lbs 9,750 lbs
22’-9” 15’-2” 8’-9” 17’-6” 8,880 lbs 9,750 lbs

23’-10” 15’-11” 9’-2” 18’-4” 7,200 lbs 9,750 lbs
24’-11” 16’-7” 9’-7” 19’-2” 5,888 lbs 9,750 lbs
25’-11” 17’-3” 10’-0” 20’-0” 5,363 lbs 9,750 lbs

27’-0” 18’-0” 10’-5” 20’-10” 4,464 lbs 9,750 lbs
28’-2” 18’-9” 10’-10” 21’-8” 3,750 lbs 9,750 lbs

29’-3” 19’-6” 11’-3” 22’-6” 3,412 lbs 9,750 lbs
30’-6” 20’-3” 11’-8” 23’-4” 3,200 lbs 9,750 lbs

* Ultimate Brace Load based on test reports and calculations.
** Knee bracing requires knee, lateral and end bracing to obtain the loads indicated.
*** Range for 45-60 degree angle.
Note: Pipe Braces should always be inspected for unusual wear or damage after each use. Any Pipe Brace
with missing parts, dents or kinks, indications of heating or other damage, should not be used until repaired.

Call 708-493-9569 www.surebuilt-usa.com 25

PAGE 26
========================================================================

Adjustable Pipe Brace (SBUP5)

Ultimate Brace Load* Ultimate Brace Load*
D V X L
w/o Knee Bracing with Knee Bracing**
29’-3” 19’-6” 11’-3” 22’-6” 8,063 lbs 9,750 lbs
30’-4” 20’-3” 11’-8” 23’-4” 7,988 lbs 9,750 lbs
31’-5” 20’-11” 12’-1” 24’-2” 7,200 lbs 9,750 lbs
32’-6” 21’-8” 12’-6” 25’-0” 6,375 lbs 9,750 lbs
33’-7” 22’-5” 12’-11” 25’-10” 5,175 lbs 9,750 lbs

34’-8” 23’-1” 13’-4” 26’-8” 4,375 lbs 9,750 lbs
35’-9” 23’-10” 13’-9” 27’-6” 3,833 lbs 9,750 lbs

36’-10” 24’-7” 14’-2” 28’-4” 3,150 lbs 9,750 lbs
37’-11” 25’-3” 14’-7” 29’-2” 2,625 lbs 9,750 lbs
39’-0” 26’-0” 15’-0” 30’-0” 2,400 lbs 9,750 lbs

40’-0” 26’-8” 15’-3” 30’-10” 2,025 lbs 9,750 lbs
41’-1” 27’-5” 15’-10” 31’-8” Not recommended 9,450 lbs
42’-2” 28’-1” 16’-3” 32’-6” Not recommended 9,000 lbs

43’-3” 28’-10” 16’-8” 33’-4” Not recommended 8,400 lbs
44’-4” 29’-6” 17’-1” 34’-2” Not recommended 7,800 lbs

45’-5” 30’-3” 17’-6” 35’-0” Not recommended 7,500 lbs
46’-6” 31’-0” 17’-11” 35’-10” Not recommended 6,975 lbs
47’-7” 31’-9” 18’-4” 36’-8” Not recommended 6,487 lbs

48’-8” 32’-3” 18’-9” 37’-6” Not recommended 6,263 lbs
49’-9” 33’-2” 19’-2” 38’-4” Not recommended 5,050 lbs

50’-8” 33’-10” 19’-6” 39’-0” Not recommended 5,663 lbs
* Ultimate Brace Load based on test reports and calculations.
** Knee bracing requires knee, lateral and end bracing to obtain the loads indicated.
*** Range for 45-60 degree angle.

Note: Pipe Braces should always be inspected for unusual wear or damage after each use. Any Pipe Brace
with missing parts, dents or kinks, indications of heating or other damage, should not be used until repaired.

26 Call 708-493-9569 www.surebuilt-usa.com

PAGE 27
========================================================================

Adjustable Pipe Brace (SBUP11A)

Ultimate Brace Load*
D V X L
w/o Knee Bracing
33’-2” 22’-2” 12’-9” 25’-6” 13,500 lbs
34’-2” 22’-10” 13’-2” 26’-4” 13,500 lbs
35’-3” 23’-6” 13’-7” 27’-2” 13,500 lbs
36’-4” 24’-3” 14’-0” 28’-0” 13,500 lbs
37’-5” 25’-0” 14’-5” 28’-10” 13,500 lbs

38’-6” 25’-8” 14’-10” 29’-8” 13,500 lbs
39’-7” 26’-5” 15’-3” 30’-6” 13,500 lbs

40’-8” 27’-2” 15’-8” 31’-4” 13,500 lbs
41’-9” 27’-10” 16’-1” 32’-2” 13,500 lbs
42’-10” 28’-7” 16’-6” 33’-0” 13,250 lbs

43’-11” 29’-4” 16’-11” 33’-10” 13,000 lbs
45’-0” 30’-0” 17’-4” 34’-8” 12,750 lbs
46’-1” 30’-9” 17’-9” 35’-6” 12,500 lbs

47’-2” 31’-6” 18’-2” 36’-4” 12,250 lbs
48’-3” 32’-2” 18’-6” 37’-2” 12,000 lbs

49’-4” 32’-11” 19’-0” 38’-0” 10,750 lbs
50’-5” 33’-8” 19’-5” 38’-10” 9,500 lbs
51’-6” 34’-4” 19’-10” 39’-8” 8,250 lbs

Pipe Braces

Ultimate Brace Load*
Part No. D*** V*** X*** L
w/o Knee Bracing
SBPB417 15’-0” to 24’-0” 13’-6” 10’-3” 17’-0” 9,750 lbs
SBPB422 19’-0” to 31’-0” 18’-1” to 19’-2” 12’-8” to 11’-1” 21’-7” 9,750 lbs
SBPB427 23’-0” to 39’-0” 22’-3” to 23’-7” 15’-7” to 13’-7” 26’-8” 7,200 lbs
SBPB432 27’-0” to 46’-0” 26’-5” to 27’-11” 18’-6” to 16’-1” 31’-8” 5,400 lbs
SBPB51232 27’-0” to 46’-0” 27’-0” to 28’-7” 18’-11” to 16’-6” 32’-6” 13,500 lbs

SBPB51237 31’-0” to 53’-0” 30’-6” to 31’-9” 21’-5” to 18’-7” 37’-6” 12,000 lbs
SBPB51242 35’-0” to 60’-0” 34’-1” to 35’-11” 23’-10” to 20’-9” 42’-6” 8,040 lbs

SBPB51252 40’-0” to 75’-0” 42’-3” to 44’-7” 29’-7” to 25’-9” 52’-6” 5,775 lbs
* Ultimate Brace Load based on test reports and calculations.
** Knee bracing requires knee, lateral and end bracing to obtain the loads indicated.
*** Range for 45-60 degree angle, minimum 2’ above center of gravity..

Note: Pipe Braces should always be inspected for unusual wear or damage after each use. Any Pipe Brace
with missing parts, dents or kinks, indications of heating or other damage, should not be used until repaired.

Call 708-493-9569 www.surebuilt-usa.com 27

PAGE 28
========================================================================

Modular Brace* – 6-5/8” Pipe

There’s no need to stock every possible brace size
when you can simply reconfigure the components
SBMR32-6
using a handful of nuts and bolts.
SBMR37-6
The patent pending components can be assembled
SBMR42-6
into three different lengths. You always have the size
you need and reduce inventory at the same time.

Safety Note

The full-moment connections require four
3/4”x2-1/2” Grade 5 (min) bolts, four structural
washers, and four 3/4” Nylock nuts, torqued to
a minimum of 150 ft-lbs.
End Connector hardware has right- and left-hand threaded rods for a combined 24” total adjustment. The End

Connectors are attached to a Triple-Slot Brace Shoe for anchoring. The type and number of bolts used with the
shoe may limit brace loading.

Modular Brace – 6-5/8” Pipe
Part No. Description Min Max Weight Ultimate Load*
SBMR76 Modular Brace 7’ Complete 6’-7” 8’-7” 100 lbs 25,250 lbs

SBMR126 Modular Brace 12’ Complete 11’-7” 13’-7” 150 lbs 25,250 lbs
SBMR176 Modular Brace 17’ Complete 16’-7” 18’-7” 190 lbs 25,250 lbs
SBMR226 Modular Brace 22’ Complete 21’-9” 23’-9” 225 lbs 25,250 lbs

SBMR326 Modular Brace 32’ Complete 31’-7” 33’-7” 383 lbs 25,250 lbs
SBMR376 Modular Brace 37’ Complete 36’-8” 38’-8” 456 lbs 22,000 lbs

SBMR426 Modular Brace 42’ Complete 41’-9” 43’-9” 499 lbs 14,440 lbs
* Loads shown is the Ultimate capacity of the brace and brace shoe. Please note that connections may be the
limiting factor and may control the design.

Each Modular Brace assembly has a right-hand and left-hand End Connector for a combined 24” adjustment.
Loads based on actual test results. The full-moment connections require four 3/4”x2-1/2” Grade 5 (min) bolts,
four structural washers, and four 3/4” Nylock nuts, torqued to a minimum of 150 ft-lbs.
See Brace Spacing Bid Chart on pages 46-47
* U.S. Patent Pending

28 Call 708-493-9569 www.surebuilt-usa.com

PAGE 29
========================================================================

Modular Brace* – 8-5/8” Pipe
SBMR42-8
As panels increase in height and weight, you can use
an even longer version of the Modular Brace. With
SBMR52-8
an 8-5/8” diameter, these components provide the
capacity for the increasing panel sizes.
You can still reconfigure the brace components with SBMR62-8
plate-to-plate bolting and always have the size you
need, while reducing inventory.

Safety Note
The full-moment connections
require four 3/4”x2-1/2” Grade 5
(min) bolts, four structural washers,
and four 3/4” Nylock nuts, torqued

to a minimum of 150 ft-lbs.
* U.S. Patent Pending
End Connector hardware has right- and left-hand threaded rods for a combined 24” total adjustment. The End
Connectors are attached to a Triple-Slot Brace Shoe for anchoring. The type and number of bolts used with the
shoe may limit brace loading.

Modular Brace – 8-5/8” Pipe

Part No. Description Min Max Weight Ultimate Load
SBMR428 Modular Brace 42’ Complete 41’-7” 43’-7” 587.3 lbs 25,250 lbs
SBMR528 Modular Brace 52’ Complete 51’-8” 53’-8” 733.6 lbs 19,850 lbs

SBMR628 Modular Brace 62’ Complete 61’-9” 63’-9” 879.9 lbs 14,440 lbs
* Loads shown is the Ultimate capacity of the brace and brace shoe. Please note that connections may be the
limiting factor and may control the design.

Each Modular Brace assembly has a right-hand and left-hand End Connector for a combined 24” adjustment.
Loads based on test results. The full-moment connections require four 3/4”x2-1/2” Grade 5 (min) bolts, four
structural washers, and four 3/4” Nylock nuts, torqued to a minimum of 150 ft-lbs.
See Brace Spacing Bid Chart on pages 46-47

Call 708-493-9569 www.surebuilt-usa.com 29

PAGE 30
========================================================================

Modular Brace* Components

Each Modular Brace assembly has a right-hand (RH)
and left-hand (LH) End Connector. In combination, the
threaded rods provide 24” of adjustment, 6” more than
conventional braces.

Each End Connector is attached to a Brace Shoe with
Triple-Slots for anchoring. The type and number of bolts
used with the shoe may limit the brace capacity.

End Connectors and Brace Shoes, including the
Nuts and Bolts used for plate-to-plate connections,
are interchangeable. The components can be used
End Connector LH (yellow) End Connector RH (green)
to assemble a Modular Brace, then reconfigured for
with Brace Shoe 3-Bolt with Brace Shoe 3-Bolt
another size.

Modular Brace* Components – 6-5/8” Pipe
Part No. Description Weight
SBMR306 Modular Pipe 30’ Only 290.3 lbs

SBMR106 Modular Pipe 10’ Only 116.8 lbs
SBMR56 Modular Pipe 5’ Only 73.4 lbs

Modular Brace* Components – 8-5/8” Pipe
Part No. Description Weight

SBMR408 Modular Pipe 40’ Only 495.3 lbs
SBMR108 Modular Pipe 10’ Only 146.3 lbs

Modular Brace* Hardware
Part No. Description Weight
SBMECRH End Connector RH Green 46.0 lbs

SBMECLH End Connector LH Yellow 46.0 lbs
SBBS3B Brace Shoe 3-Bolt 19.2 lbs
SBMRB34212 Bolt 3/4”x2-1/2” Grade 5 —

SBMRW Washer 3/4” Structural —
SBMRN34 Nylock Nut 3/4” —

* U.S. Patent Pending

30 Call 708-493-9569 www.surebuilt-usa.com

PAGE 31
========================================================================

HGA Bracket*

The Helical Ground Anchor (HGA) Bracket provides a simple
connection point between HGAs and tilt-up braces. The design
eliminates the need to remove, then reattach, pipe brace shoes.
The pipe brace shoe bolts directly to the bracket.

The HGA Bracket is available in a 1-Bolt, 2-Bolt or 3-Bolt
configuration. The tilt-up panel engineering, bracing and
anchoring requirements will determine which HGA Bracket is the
most effective.

Each configuration of the HGA Bracket comes with 3/4” x 3”
grade 5 bolts for fastening the HGA Bracket to the shoes and a
grade 8 bolt and nut for fastening the bracket to the HGA.

HGA Brackets
Ultimate
Part No. Description SWL* (lbs)
Load (lbs)
Standard Transitional
SBSHC 15,000 24,000
Brace Connector (STBC)
SBHGA1PB HGA Bracket 1-Bolt 20,000 24,000
SBHGA2PB HGA Bracket 2-Bolt 20,000** 24,000
SBHGA3PB HGA Bracket 3-Bolt 20,000** 24,000
* Safe Working Load based on 1.67:1 safety factor.
** Capacity of Helical Ground Anchor may control design.
1

2 B

3

3/4” x 3” Flange Coil Brace
Bolt Part #SBBB34G
4 HGA to STBC Connection: 3/4”x4”
Grade 5 Bolt and Nut.
22.5° 1-Bolt, 2-Bolt, and 3-Bolt HGA
.018 3/4″ COIL
THREAD
Bracket configuration without and
.148
.167 STBC to Pipe Brace Co .1 n 25 nection:
w
br
i
a
th
c k
b
e
ra
t,
c
b
e
o
s
lt
h
i
o
n
e
c
.
lu
N
d
u
e
t
d
i
.
s welded to
5/8”x4” Grade 8 Bolt and Nut.
DETAIL A
.490
.167
n.750 A
B
Note: The load-ratings of the helical ground anchor, tilt-up brace and HGA Bracket must be considered
simultaneouslAy for maximum allowable capacity and spacing.
DATE
0
: 4-10-2025
n1.570 N c * o U o m 1.t . 3e6 S p 3 : . o H P n e e a l n t i e c ts n a l t m G P u r e s o n t u d b n i e d n c g A o n n2. c 9s6 h 3id o e r, r e P d ip w e h B e r n a c e e n , g a in n T e I d TLE 3 e / : / o 4 r ” i r n D s I g A o . a x il 3 c ” b S o r E a n RR c d A iT i n t E i gD o F n c LA s o N n G m E fi aC g Oy u IL r b B a O e S t H L E i T 1 E o T t : O 1 h F n D 1 e R . C A H W A E P N Cc P : K R D E O o D D V M : E n D : trolling factor. Capacities for all
Call 708-493-9569 A PH 84 O 0 N S E . : 2 ( 5 7 T 08 H 1 ) . A 1 4 8 V 93 0 E – . 9 4 5 B w 6 E 9 L – L F W w A O X O : w ( D 7 , 0 I 8 L ) . 6 4 s 0 9 1 3 0 – u 9 4 601 re N b IN O PA R T A T N P E O H C WY E : PI O u S R T H R E M H M O D E R E PI P R L T S A E R I Y A S N N i O W W I O F O Y D O IF I N N l T I U R S S G H C O M U P t O T F I A R S R UI O S T O E T T – I U N B O H H TR U I N E IH B N u E I L E I S C B T P T O O U E W A C L DI N RR L EO . T T T s I M T A O T I P N E R A U E N D T N A a D N F I Y O S D M L R . 0 L E E A E 0 E . S C 0 0 C N . . R S 0 A . . I T S . 0 A U M 0 N . c I O I 0 N . N . O O G A . . 0 T . C . L L N . L N . . H . E E . . S E . S . S . S E . :o . : . S 3 : . . . S R ± A . : . ± ± . W R 0 ± ± O 1 0 . E I 0 T 1 0 / . m S 0 3 . ° H 6 I 0 E 3 N 2 3 E 1 1 ” S R 0 I P N W E C I C H S I E E F S I S E P D E R C E IF V S I : E IZ D S E C : B N M A . L A T E . T S : E . R F I I A N L G IS : R H: ADE 5 STEE W L EIGH .6 T: 2LB P S A D R W T G N . O 2 N : O: 31

PAGE 32
========================================================================

Helical Ground Anchor

The Helical Ground Anchor provides temporary and reusable
ground support method for anchoring braces.

HGAs provide an engineered alternative to slab bolting or
concrete deadmen. The anchor is a square steel shaft with
helix plates that “screws” into the ground with continuous
downward force. The anchor will establish a load capacity for
subsequent brace attachment (depending on the soil condition
and strata).

HGAs are both economical and effective. Benefits include:
eliminating forming and handling a concrete deadman at each
brace location, eliminating drilling, bolting and patching the
floor slab at each brace location, and a verifiable load rating in
all soil conditions from the torque installation method.

HGAs provide a quick installation and removal method
A skidsteer with a torque motor
for anchor placement. Compatible with Helical Anchor
attachment is used to install the Helical
Extensions, HGA Brackets and Pipe Braces.
Ground Anchor at the prescribed angle
and depth for bracing.

The lower two flights on the The HGA Extension Drive Head Unit comes with skidsteer mount and
HGA have “C” shape chisel has standard straight transport frame.
flight finish. Top flight has flight finish.
standard straight flight finish.

32 Call 708-493-9569 www.surebuilt-usa.com

PAGE 33
========================================================================

Helical Ground Anchor Installation

1. The Helical Ground Anchor should be installed by a trained professional using a skidsteer with a torque
motor. Do not weld, cut or alter the Helical Ground Anchor. Do not use worn or damaged components.
2. All subsurface structures and utilities must be properly marked before Helical Ground Anchor installation
begins. Provide horizontal clearance of 5’ in all directions.
3. The Helical Ground Anchor must be installed with continuous downward pressure to a minimum torque of
2,400 ft-lbs. A Helical Anchor Extension is necessary if the minimum is not achieved.
4. A field log of the site location and torque value of each and every Helical Ground Anchor is required for all
construction projects. Prevent soil erosion at all anchor locations.
5. The Helical Ground Anchor must be installed in line with the brace for maximum capacity. Alternative
geometry requires appropriate bracing and anchoring calculations.
6. The HGA Bracket, with optional single or double mounting plate, must be used for the brace connection.
The bracket attaches to the anchor and the brace shoe bolts directly to the bracket plate.

Helical Ground Anchor*

Size of # of Helical SWL Ultimate
Part No. Description Length
Square Bar Helicals Diameters (lbs) Load (lbs)
SBHA7 7’ HGA 1-1/2” 84” 3 8”-10”-10” 12,000 24,000
SBHAE HGA Extension 1-1/2” 42” 1 10” 15,000 30,000
SBDRIVEHEAD HGA Drive Head Unit – – – – – –
* Minimum torque for product is 2,400 ft-lbs.
* Design by an experienced professional only.
* Installation by a trained contractor only.
*3/4” Grade 5 Bolt for connection to HGA

1 2

The HGA Bracket sleeves over the
Helical Ground Anchor and is available
with a double or single mounting plate
option for braces. 3 4

Call 708-493-9569 www.surebuilt-usa.com 33

PAGE 34
========================================================================

Concrete Screw Anchor Bolt

A screw anchor is used to with the Brace Shoe to secure each Pipe Brace
to the concrete floor. The load-rated, concrete screw anchor bolt has a
flanged head and unthreaded shaft, allowing for the thickness of the shoe.

Concrete Screw Anchor Bolt

Part No. Description Slab SWL*
SBTHD345G Concrete Screw Anchor Bolt 3/4”x5” Galv 5” 5,200 lbs
SBTHD346G Concrete Screw Anchor Bolt 3/4”x6” Galv 6” 7,500 lbs

SBTHD347G Concrete Screw Anchor Bolt 3/4”x7” Galv 7” 9,000 lbs
* Safe Working Load (SWL) using 2:1 safety factor in 3,000 psi concrete.
Loads Based on testing with 55 degree brace angle

Drill hole Clean hole Torque bolt Check fit

Warning:
1. Concrete must have a minimum of 3,000 psi compressive strength.
2. Do not use the Concrete Screw Anchor Bolt in concrete floors thinner than 5”.
3. Edge distance should be a minimum of 12” to center of holes.
4. Do not reuse Concrete Screw Anchor Bolts.

Installation:
1. Drill holes at 90O angle to the surface with a 3/4” carbide-tipped bit.
2. Drill a minimum of 5-3/4” deep for 6” anchor.
3. Clean the drilled holes with compressed air or blow-out bulb.
4. Only use new Anchors with clean and undamaged threads.
5. Place Brace Shoe over the hole and position anchor.
6. Securely tighten anchor using a 3/4” impact wrench to 100 ft-lbs.
7. Use 3/4” F436 Structural Washer where needed.

Other bolts and brands are acceptable. Bolts must be 3/4” diameter and capacities confirmed with the
manufacturer before installation.

34 Call 708-493-9569 www.surebuilt-usa.com

PAGE 35
========================================================================

Taper Bolt

A reusable bolt and disposable expander nut for
temporary brace installations.

• Removable bolt for temporary anchoring.
• Required hole diameter equals bolt dimension.
• Expander nut adjusts for variation in hole size.
• Taper Bolt assembly will work in “bottomless” hole.
• Torqued to obtain high-strength shear load value.
• Withstands static and vibratory loads.
• Bolt can be removed, cleaned and reused.

3/4” Taper Bolts work with all Braces
The Taper Bolt and Nut are ideal for anchoring and
1” Taper Bolts work with Modular Brace Only
then removing tilt-up braces.
Taper Bolt and Nut*
Ultimate***
Min
Bolt Min Min
Part No. Torque Single Bolt
Size** Slab Embed
(ft/lbs)
Tension (lbs) Shear (lbs)
SBTB34418 3/4”x4-1/8” 4” 250 3-3/8” 7,200 14,440
SBTB34512 3/4”x5-1/2” 5” 250 4-1/2” 11,900 24,800
SBTB347 3/4”x7” 6-1/2” 250 6” 11,900 27,916
SBTB1558 1”x5-5/8” 5” 550 4-5/8” 12,900 25,900
SBTB1634 1”x6-3/4” 6” 550 5-3/4” 17,900 35,950
SBTB1714 1”x7-1/4” 7” 550 6-1/4” 20,300 36,257
SBTBN34 3/4” Nut
SBTBN1 1” Nut

* Standard Grade 5, zinc-plated finish. Other metals and finishes available on request.
** Required hole diameter equals bolt dimensions.
*** Ultimate load in 3,000 psi concrete. Tested by Pittsburgh Testing Laboratory PG-2170.
Loads Based on testing with 55 degree brace angle

1. Drill a hole the same diameter as the Taper Bolt using the Brace Shoe as a template.
2. Clean hole and surrounding area with compressed air.
3. Drive Taper Bolt and Expander Nut into place leaving clearance for subsequent tightening.
4. Tighten Taper Bolt to recommended torque setting to expand nut.
5. For multiple Taper Bolt installation use an Impact Wrench for productivity.
6. Unscrew the Taper Bolt for removal. Expander Nut remains in hole.
7. Clean, lubricate and save the Taper Bolt for the next installation.

Call 708-493-9569 www.surebuilt-usa.com 35

PAGE 36
========================================================================

Panel Base Connector*

The Panel Base Connector is easy to position and
fasten at the bottom edge of the form. It can be
placed in either a face-up or face-down orientation
depending on the forming and handling preference.

The high-strength, drill-in 3/4”x10” screw anchor
provides an immediate and secure connection when
tightened. There is no grout set-up or wait time.

The connection is centered in the concrete panel,
minimizing moment and eccentric forces in the
design, and resisting in-plane tension and out-of-
plane shear forces.

The connection provides a nominal capacity in
excess of 10 Kips for shear and tension, meeting the
applicable ACI requirements. Note: 7” Screw Anchor engagement required

The relatively small access area is easy to grout, Panel Base Connector Kit
providing complete embedment and encapsulation
Part No. Description
for corrosion protection.
SBPBC34HD10KIT PBC Kit w/10” Screw Anchor
Meets ACI integrity requirements of ACI-318 -11 SBPBC34HD12KIT PBC Kit w/12” Screw Anchor
16.5.1.3(b) ACI318-14 16.2.4.3(b), ACI-318-19
* Panel Base Connector w/ 3/4” x 12” Screw Anchor
16.2.4.3 (b), and ACI 551.2R-15 Chapter 8.
for use when space between panel and footing is
between 2-3”
Average tensile test value
is 34,896 lbs in 6,555 psi
concrete. Conversion from psi
to tensile:
6000 psi = 33,381 lbs
5000 psi = 30,472 lbs
4000 psi = 27,255 lbs
3000 psi = 23,604 lbs

Testing observed and verified
by a Professional Engineer.

Drill a 3/4” x 7” hole, using Place a 3/4” x 10” screw Fill the cavity with
a 3/4” x 24” bit, through the anchor though the grout and finish flush
opening of the connector into connector and footing or with surface.
the footing or foundation. foundation, then torque to
150 ft-lbs.

* Patent No.: U.S. 11,891,790

36 Call 708-493-9569 www.surebuilt-usa.com

PAGE 37
========================================================================

Slant Anchor*

The Slant Anchor assembly connects tilt-up or precast panels to
the foundation. The assembly includes a load-rated Slant Anchor,
foam Void Former, high-strength Ductile Bar and pre-packaged
Flowable Grout.

The Slant Anchor is integral to panel design and planning. The
anchors are positioned and reinforced in each panel during
concrete forming operations. The foam Void Former covers the
connection sleeve during concrete placement.

Once a completed concrete panel is ready for installation, the foam
Void Former is removed. The connection sleeve is now visible and
accessible for subsequent anchoring.

Each concrete panel is positioned on the foundation and braced.
A hole is drilled into the foundation footing using the connection
sleeve as a guide.

The Slant Anchor assembly provides
The hole is then partially grouted, the Ductile Bar inserted, and the
a load-rated panel connection and
remaining grout used to fill the sleeve. This grouted connection
a 37% savings compared to typical
anchors the panel without welding or bolting.
embed welding or bolting.
The working load of the Slant Anchor is 9,000 lbs for uplift,
horizontal and shear forces, at a 3:1 safety factor. This meets the
tensile strength requirements of ACI-318-14 section 16.2.4.3 (b),
ACI-318-19 section 16.2.4.3 (b), and ACI 551.2R-15 Chapter 8.
Slant Anchor Assembly*
Part No. Type Panel Width Finish**
SBTSAC Standard 7” minimum Painted
SBPSAC Slim 5-1/2” to 7” Painted
* Assembly includes anchor, void former, ductile bar and grout.

** Optional galvanized finish on request.

The Slant Anchor is
simply positioned and
nailed to the form.

* U.S. Patent Pending
Standard Slim

Call 708-493-9569 www.surebuilt-usa.com 37

PAGE 38
========================================================================

SureGrip

SureGrip provides anchoring for all types of bolted
joints when embeded in concrete, even if the screws
need to be removed and attached again.

SureGrip is an extruded plastic composite made
from recycled plastics and designed to be a durable,
maintenance-free alternative to using treated lumber.

The color pigments used in SureGrip provide an
environmentally friendly UV protection that retains the
Cast SureGrip in concrete and anchor as needed.
original color for longer while also providing a 35-year
guarantee against rot and cracks.
Solid concrete walls and concrete products can now
use SureGrip to immediately secure bolts and screws
for many applications as well as provide protection for
the insulation in insulated concrete wall applications.

SureGrip embedment strips are cast into the concrete
in precast forming applications. Some applications
include fastening windows, doors, and parapet
attachments to the SureGrip. It can also be fastened to
edge forms adjacent to the insulation on the perimeter SureGrip cast in solid Flashing cap fastened to
of insulated concrete panels to protect the insulation precast wall for fastening SureGrip using #14×1-1/2”
from damage. flashing cap on parapet. NovaTM / YukonTM fasteners.

Fasten SureGrip to window and door openings, and Flashing cap fastened to SureGrip using #14×1-1/2”
parapet attachments as specified. NovaTM / YukonTM fasteners.

SureGrip

Part No. Description Height Width Length Density
SBSGES SureGrip Embedment Strip 1-3/8” 1-3/8” 6’ – 6-5/8”’ 59 lb/ft3
Full pallet contains 256 embedment strips

38 Call 708-493-9569 www.surebuilt-usa.com

PAGE 39
========================================================================

Edge Connector

The Edge Connector is a rebar-winged embed
designed for tilt-up concrete applications. The “wing”
is tied into the panel reinforcing steel, with the “flat”
positioned at the panel edge for later welding.

The rectangular “flat” on the Edge Connector
provides for a thicker, more reliable, field welding
surface between adjoining panels. The rectangular
shape exhibits greater weld strength, with less
variability, compared to typical round slugs.

The Edge Connector exhibits excellent performance
in Horizontal Shear, Tension and Vertical Shear,
making it suitable for tilt-up concrete applications,
Edge Connectors are used to join adjacent precast or
such as panel-to-panel connections, roof slabs and
tilt-up concrete elements.
industrial walls.
Edge Connector
Horizontal Vertical
Part No. Description Type Tension*
Shear* Shear*
SBEC4R Edge Connector #4 w/1” Flange A706 3,020 lbs 7,210 lbs 16,250 lbs
SBEC4RSS Edge Connector #4 w/1” Flange 2304SS 3,020 lbs 9,340 lbs 18,960 lbs
SBEC5R Edge Connector #5 w/1-1/2” Flange A706 6,390 lbs 11,740 lbs 27,680 lbs
SBEC5RSS Edge Connector #5 w/1-1/2” Flange 2304SS 6,390 lbs 12,590 lbs 32,670 lbs
* Ultimate load capacities.

Edge Connector Former*
Part No. Description

SBEC4F Edge Connector Former #4 1” (Red)
SBEC5F Edge Connector Former #5 1-1/2” (Blue)
Former for Edge Connector positioning.
* Plastic Former accurately positions Edge Connector in form.

Call 708-493-9569 www.surebuilt-usa.com 39

PAGE 40
========================================================================

Edge Form Bracket 6×8, 9×11

Stop cutting lumber blocks for bracing and start
forming faster with the reusable Edge Form Bracket.

The one-piece plastic design is a wedge-shape that
braces tilt-up edge forms.

The top of the Edge Form Brackets should always
be positioned below the overall form height to not
interfere with concrete screeding or finishing.

Edge Form Bracket

Part No. Description
SBEFG6X8 Edge Form Bracket 6”x8” Nail, screw or glue to lumber and concrete. Then
brackets can be stripped, stacked, saved and reused.
SBEFX9X11 Edge Form Bracket 9”x11”

Adhesives & Cleaner

Construction Adhesive
A high-strength, fast-drying, pressure-sensitive
adhesive used for positioning chamfers, reveals
and rustications in tilt-up casting beds. Suitable for
concrete, metal, plastic and wood surfaces.

All Weather Adhesive
100% solids, All weather, high-strength adhesive Construction Adhesive All Weather Adhesive
used for positioning chamfers, reveals and aerosol can – canister tank sausage pack
rustications in tilt-up casting beds. Suitable for
concrete, metal, plastic and wood surfaces.

Adhesive Cleaner
Designed to help clean up adhesive residue.
Canister Gun wAdjustable Caulking Gun for 20oz,
Flow Rate Bulk, Cartridge, Sausage

Adhesives & Cleaner

Part No. Description Packaging
SBFCA14 Construction Adhesive – LVOC inverted aerosol spray – 14oz can 12/case, 108 cases/plt
SBFAWA20 All-Weather Adhesive – 20 oz sausage pack – 100% solids 12/case, 45 cases/plt

SBFCA28 Construction Adhesive – canister tank – 28 lbs 36/plt
SBFAC5 Adhesive Cleaner – 5 gallon pail 36/plt

SBFCGAF Canister Gun w/Adjustable Flow –
SBFCH12 Canister Hose – 12’ Length –
SBCGNB620AL Caulking Gun for 20oz, bulk, cartridge, sausage –

40 Call 708-493-9569 www.surebuilt-usa.com

PAGE 41
========================================================================

Tilt-Up Profiles

Detailed lines, chamfered edges and smooth reveals for a better concrete panel appearance.

Saw Cut Cover
A semi-rigid, plastic t-strip used to seal concrete saw cut joints before
pouring tilt-up panels.

Saw Cut Cover
Part No. Description lf/bundle
SBSCC2 3/8” Top x 5/8” Deep x 8’ Cover Strip 1000

Single Chamfer
A plastic or wood profile to make smooth concrete panel edges.

Single Chamfer
Part No. Description lf/bundle

SBSCW 3/4” x 8’ Wood Chamfer 400
SBSCP 3/4” x 12’ Plastic Chamfer 300

Double-Chamfer
A double-chamfer plastic profile used on both the top and bottom of
lumber forms to create smooth concrete panel edges.

Double Chamfer
Part No. Description lf/box

SBDC1534 1-1/2” x 3/4” x 10’ Double Chamfer 200

Rustication
An easy-to-install rustication profile for tilt-up panels.

Rustication

Part No. Description (AxBxC) lf/bundle
SBSTIX1 2-1/4” x 3/4” x 3/4” x 8’ Trapezoid 400
SBSTIX3 2” x 1/2” x 3/4” x 8’ Trapezoid 400

SBSTIX6 2-3/4” x 2” x 3/4” x 8’ Trapezoid 400
SBSTIX9 1-1/2” x 3/4” x 8’ Triangle 560

Call 708-493-9569 www.surebuilt-usa.com 41

PAGE 42
========================================================================

Bar Support

Pro Tilt Chair
3/4” to 3”, in quarter inch increments. Each size has two cover
heights to reduce potential inventory storage requirements. The
extra wide footprint contributes to a more sturdy and heavy duty Pro Tilt Chair
chair that stays in place better than lighter weight alternatives.

Tilt Chair
Tilt Chairs have a wide, stable base that works well in architectural
applications and carries necessary loads and protect wood forms. Tilt Chair
Large leg spacing for easy tying to rebar, maximum concrete flow
and consolidation.

H Chair H Chair
Lightweight plastic supports for reinforcing steel within concrete.
Part No. Description
H Chair
SBSH100 H Chair 1”
SBSH150 H Chair 1-1/2” High Chair
Designed to straddle a lower rebar mat, these chairs have a
SBSH200 H Chair 2”
wide, stable base with a footprint that is designed to work well in
SBSH250 H Chair 2-1/2” architectural applications, yet able to carry very heavy loads and
SBSH300 H Chair 3” protect wood forms. High Chair
SBSH350 H Chair 3-1/2”
SBSH400 H Chair 4” Pro Chair
The Pro Chair delivers value and performance through stablility
SBSH450 H Chair 4-1/2”
and easy-to-read height markers. Available in 1/2” cover height
SBSH500 H Chair 5”
increments, chair selection is simple and the industry-leading stack
SBHCAP512 H Chair 5-1/2” efficiency reduces costs. Better stacking means the chairs are
Pro Chair
less costly to store, less costly to ship and less costly to place in
SBSH600 H Chair 6”
the field. Pro Chairs straddle lower mats, carry heavy loads, are
easy to tie, and have a minimal footprint for tilt-up and architectural
applications, while protecting costly form work.
Slab-On-Grade Chair
Slab-On-Grade Chair
Integrated sand plate for support and stability on soft surfaces.
Slab-On-Grade Chair
Part No. Description Slab Bolster
Plastic slab bolster with end lock for connecting longer lengths and
SBPCC1112 SOG Chair 1:1-1/2”
secure fit.
SBPCC2212 SOG Chair 2:2-1/2”
SBPCC3312 SOG Chair 3:3-1/2”
See all Plastics Bar Supports by scanning QR Code here:
SBPCC4412 SOG Chair 4:4-1/2”
Slab Bolster
42 Call 708-493-9569 www.surebuilt-usa.com

PAGE 43
========================================================================

Patch Caps

Patch caps are used to cover the lifting and bracing
insert holes.

Patch Caps

Part No. Description
SBRLPC22KP Patch Cap (5/8” Square Insert)
SBPATCHCAPBI Patch Cap (3/4” Brace Insert)

Shims

Shims provide quick adjustment when installing
panels on slightly uneven footings. The shims are
formed with a corrugated face that prevents them
from sliding across each other when stacked.

Each pack contains six 4”x6” shims with an overall
Patch Caps
thickness of 1-1/16″. The pack contains three 1/4″
black shims, two 1/8″ blue shims and one 1/16″ white Part No. Description
shim made with HIPS material (8,000 psi minimum).
SBSHIMPK Shim Pack Set (6 pcs)
Slab Protector

Slab Protectors are a great way to protect concrete
floors when installing tilt-up panels. Slab Protectors
are made from rigid, durable PVC and prevent
damage to new floors.

Eliminates Repair – Slab Protector saves your floors
from damage. Crews won’t spend valuable time and
money repairing scratched or damaged floors. The integral plastic edge
protects the concrete when
Improves Quality – Crews using Slab Protector can handling and moving tilt-up
walk away from completed concrete floors with pride. panels.

Protects Floor – Slab Protector remains in place Installation:
along the edge of the panel to protect concrete floors 1. Fasten two Slab Protectors, one in each corner,
from damage during handling. along the bottom edge of the form.
2. If the width is greater than 20 feet, then fasten
another Slab Protector at the center.
Slab Protector 3. Place and vibrate concrete, making the Slab

Part No. Description Protector an integral part of the panel.
4. Strip the forms to expose the plastic edges of the
SBSEP24 Slab Protector 24”
Slab Protector.
5. Use the plastic edges to protect the concrete
when handling and moving panels.
Call 708-493-9569 www.surebuilt-usa.com 43

PAGE 44
========================================================================

FRP Truss

The truss develops strength and rigidity from a fiber-
reinforced design. Two parallel #2 FRP deformed
reinforcement bars are attached inline or on either
side of the wave of #2 FRP reinforcement bar using
connectors every 8”. Foam insulation is placed
between lengths of truss, connecting the top and
bottom concrete.

The fiber-reinforced material improves the thermal
efficiency of “sandwich” panels and reduces cold
bridging. The truss shape provides composite action
between the top and bottom concrete, supporting
all working loads, including stripping, handling and
installing tilt-up panels. FRP Truss data available for
sandwich wall design software, contact SureBuilt
Engineering for assistance.

FRP Truss
Part No. Description H L l d r *Wythe Dimensions

SBFRPT610 FRP Truss 6”x10’ 6” 10’ 8” #2 GFRP #2 GFRP 3-2-3 / 3-3-3
SBFRPT710 FRP Truss 7”x10’ 7” 10’ 8” #2 GFRP #2 GFRP 3-3-3 / 3-4-3
SBFRPT810 FRP Truss 8”x10’ 8” 10’ 8” #2 GFRP #2 GFRP 3-4-3 / 3-5-3
SBFRPT910 FRP Truss 9”x10’ 9” 10’ 8” #2 GFRP #2 GFRP 3-5-3 / 3-6-3

H – Wave height (out-to-out)
L – Total truss length
l – Wave step (15 loops per 10’ Truss)
d – Diameter of the diagonal rod
r – Diameter of runners
* Common wythe dimesions, actual wythe and insulation dimentions can vary
Note: 1-1/2” minimum loop embedment

Contact SureBuilt Engineering for assistance (813-606-5727).

44 Call 708-493-9569 www.surebuilt-usa.com

Diagram label: Minimum loop Embedment is 1 1/2″

PAGE 45
========================================================================

FRP Truss Installation

Chairs and reinforcement are placed in Concrete (bottom wythe) is placed. First row of insulation set against edge
tilt-up bed. form.

First row of truss is placed against insula- Second row of insulation set against first Second row of truss is placed against
tion and concrete consolidated. row of truss. insulation and concrete consolidated.

Third row of insulation set against second Third row of truss is placed against insula- Final piece of insulation is installed.
row of truss. tion and concrete consolidated.

Face reinforcement is installed. Top concrete wythe is placed.

Note: WWR (reinforcement) shown in single plane.
WWR recommended for use with truss to simplify site-cast insulated panels.

Contact SureBuilt Engineering for assistance (813-606-5727).

Call 708-493-9569 www.surebuilt-usa.com 45

PAGE 46
========================================================================

Brace Spacing Bid Chart

Brace Specifications* (see notes)
SBPB417 SBPB422 SBPB427 SBPB432 SBPB51232 SBMR326 SBMR326 SBPB51237 SBMR376 SBMR376
22’-0” 22’-0” 32’-0” 32’-0” 32’-0” 37’-0” 37’-0”
17’-0” 22’-0” 32’-0”
Fixed Fixed Modular Modular Fixed Modular Modular
Fixed Fixed Fixed
w/5’ Ext w/10’ Ext w/SBI w/DBI w/5’ Ext w/SBI w/DBI
Pipe diameter 4 in 4 in 4 in 4 in 5-1/2 in 6-5/8 in 6-5/8 in 5-1/2 in 6-5/8 in 6-5/8 in
Total length 17 ft 22 ft 27 ft 32 ft 32 ft 32 ft 32 ft 37 ft 37 ft 37 ft
Ultimate load* 9,750 lbs 9,750 lbs 7,200 lbs 5,400 lbs 13,500 lbs 15,000 lbs 25,250 lbs 12,000 lbs 15,000 lbs 22,000 lbs
* Ultimate load based on shoe and brace only.
Brace Spacing* in Feet (see notes)
SBPB417 SBPB422 SBPB427 SBPB432 SBPB51232 SBMR326 SBMR326 SBPB51237 SBMR376 SBMR376
22’-0” 22’-0” 32’-0” 32’-0” 32’-0” 37’-0” 37’-0”
17’-0” 22’-0” 32’-0”
Fixed Fixed Modular Modular Fixed Modular Modular
Fixed Fixed Fixed
w/5’ Ext w/10’ Ext w/SBI w/DBI w/5’ Ext w/SBI w/DBI
50’ height 7.09 8.87 13.01
45’ height 3.55 8.88 9.87 16.61 9.04 11.30 16.57
40’ height 5.30 4.65 11.63 12.93 21.76 11.84 14.80 21.71
35’ height 7.20 6.32 15.79 17.55 29.53 16.07 20.09 29.47
30’ height 11.49 10.22 8.97 22.43 24.92 41.95
25’ height 13.97 17.56 15.62
20’ height 23.42
* Calculations based on solid panels with 80 mph wind speed in worst condition.
Bid Spacing Chart Assumes:
1. Minimum 20 foot wide panel. Minimum of two braces per panel. Round up to next integer.
2. Assumes two feet below finished floor. Different floor dimension may change spacing and height limits.
3. Brace bolt or concrete slab may be limiting factor for spacing and capacity.
Contact SureBuilt -Tampa if further assistance is necessary (813) 606-5727
Bracing Guidelines
1. Do not skew braces more than 5%. See figure on right.
2. Locate brace inserts 1 foot or more from all concrete edges and floor slab joints, otherwise
brace may interfere with rigging.
3. Locate brace inserts to provide clearance between the lifting hardware and braces.
4. Locate brace inserts symmetrically about the panel’s center line when possible.
5. Locate the first brace insert from each end of the panel at a distance no greater than 25 per-
90o
cent of the panel’s width or 10 feet, whichever is less.
6. Consider tributary widths when checking capacity on braces.
7. Brace inserts should not be placed lower than 60% of the panel’s height and not less than X
5% of the panel’s height above the panel’s geometric centroid or mass center of gravity,
whichever is greater.
8. Brace angle shall not exceed 60 degrees. At angles higher than 60 degrees, panel weigh
X
may start bearing on brace.
20
5%
Max. Skew

46 Call 708-493-9569 www.surebuilt-usa.com

[Text from diagrams]
Diagram labels: 90°; X; X/20; 5% Max. Skew

PAGE 47
========================================================================

Brace Specifications* (see notes)
SBPB51242 SBMR426 SBMR426 SBMR428 SBMR428 SBPB51252 SBMR528 SBMR528 SBMR628 SBMR628
32’-0” 42’-0” 42’-0” 42’-0” 42’-0” 32’-0” 52’-0” 52’-0” 62’-0” 62’-0”
Fixed Modular Modular Modular Modular Fixed Modular Modular Modular Modular
w/10’ Ext w/SBI w/DBI w/SBI w/DBI w/20’ Ext w/SBI w/DBI w/SBI w/DBI
Pipe diameter 5-1/2 in 6-5/8 in 6-5/8 in 8-5/8 in 8-5/8 in 5-1/2 in 8-5/8 in 8-5/8 in 8-5/8 in 8-5/8 in
Total Length 42 ft 42 ft 42 ft 42 ft 42 ft 52 ft 52 ft 52 ft 62 ft 62 ft
Ultimate Load* 8,040 lbs 14,440 lbs 14,440 lbs 15,000 lbs 25,250 lbs 5,775 lbs 15,000 lbs 19,850 lbs 14,440 lbs 14,440 lbs
* Ultimate load based on shoe and brace only.

Brace Spacing* in Feet (see notes)
SBPB51242 SBMR426 SBMR426 SBMR428 SBMR428 SBPB51252 SBMR528 SBMR528 SBMR628 SBMR628
32’-0” 42’-0” 42’-0” 42’-0” 42’-0” 32’-0” 52’-0” 52’-0” 62’-0” 62’-0”
Fixed Modular Modular Modular Modular Fixed Modular Modular Modular Modular
w/10’ Ext w/SBI w/DBI w/SBI w/DBI w/20’ Ext w/SBI w/DBI w/SBI w/DBI
85’ height 4.17 4.17
80’ height 4.77 4.77
75’ height 5.54 5.54
70’ height 2.19 5.70 7.54 6.49 6.49
65’ height 2.60 6.75 8.93 7.69 7.69
60’ height 3.54 6.36 6.36 6.61 11.13 3.12 8.10 10.72 9.23 9.23
55’ height 4.32 7.75 7.75 8.05 13.56 3.80 9.87 13.06 11.24 11.24
50’ height 5.36 9.62 9.62 9.99 16.82 4.71 12.24 16.20
45’ height 6.83 12.26 12.26 12.73 21.43 6.01 15.60 20.64
40’ height 8.94 16.06 16.06 16.68 28.08

* Calculations based on solid panels with 80 mph wind speed in worst condition.
Bid Spacing Chart Assumes:
1. Minimum 20 foot wide panel. Minimum of two braces per panel. Round up to next integer.
2. Assumes two feet below finished floor. Different floor dimension may change spacing and height limits.
3. Brace bolt or concrete slab may be limiting factor for spacing and capacity.
Contact SureBuilt -Tampa if further assistance is necessary (813) 606-5727

Bracing Guidelines
1. Do not skew braces more than 5%. See figure on right.
2. Locate brace inserts 1 foot or more from all concrete edges and floor slab joints, otherwise
brace may interfere with rigging.
3. Locate brace inserts to provide clearance between the lifting hardware and braces.
90o
4. Locate brace inserts symmetrically about the panel’s center line when possible.
5. Locate the first brace insert from each end of the panel at a distance no greater than 25 per-
cent of the panel’s width or 10 feet, whichever is less. X
6. Consider tributary widths when checking capacity on braces.
7. Brace inserts should not be placed lower than 60% of the panel’s height and not less than
5% of the panel’s height above the panel’s geometric centroid or mass center of gravity,
X
whichever is greater.
20
8. Brace angle shall not exceed 60 degrees. At angles higher than 60 degrees, panel weigh 5%
may start bearing on brace. Max. Skew
Call 708-493-9569 www.surebuilt-usa.com 47

[Text from diagrams]
Diagram labels: 90°; X; X/20; 5% Max. Skew

PAGE 48
========================================================================

Coatings and Finishes

Products manufactured by SureBuilt Concrete Forms & Accessories can be supplied in several different
coatings or finishes to meet specific corrosion requirements. Whenever the coating or finish is not specified,
the standard Plain product will be supplied.

Plain
Uncoated steel, commonly referred to as Plain, Black, Basic or Raw, will corrode when exposed to the
environment on project sites.

Mechanical Plating
An effective means of applying zinc, tin, or other ductile metals or mixtures of ductile metals to metal
substrates – usually steel. In the mechanical plating process, impact energy is transferred from a rotating
open – ended oblique barrel through glass beads, resulting in the cold-welding of fine metal dust particles
to the substrate. The resulting deposit is slightly porous, matte in finish, and provides corrosion protection to
the articles so plated without introducing hydrogen embrittlement into the part. It is used widely to provide
corrosion protection.

Electroplating
Can be a bright shiny or sometimes dull zinc finish, generally .0002 to .001 inches thick. Degree of corrosion
protection will vary and is often dependent on the severity of the particular environment.

Hot-Dip Galvanizing
Semi-bright to a very dull finish, much heavier coating than the Electroplating process. HDG provides a higher
degree of corrosion protection than the Electroplate, but is not suitable for threaded products or any tight fitting
items. High carbon steels are not suitable for HDG.

Epoxy Coating
A slick, shiny epoxy coating applied to a finished product by means of the electrostatic or fluidized bed method.
Coating thickness will vary from .005 inches to .012 inches. Epoxy coatings provide very effective corrosion
protection in hostile environments such as around or over salt water, or high chemical contaminated areas.

Guarding Against Embrittlement

Carbon steels, cold-worked steels, heat-treated steels are susceptible to embrittlement in electroplating
operations, from either or both the cleaning/pickling or coating process. Any steel having been severely cold-
worked must be stress-relieved before baking and prior to either electroplating or HDG.

Any steel of significant high-strength or high-carbon susceptible to hydrogen embrittlement during the
electroplating or HDG process must be baked before the coating process is started to drive out excess
hydrogen. Some items are not suitable for HDG because of the material properties. Contact SureBuilt
Technical Service for further information.

48 Call 708-493-9569 www.surebuilt-usa.com

PAGE 49
========================================================================

Warnings

Warning
Always follow instructions of product manufacturers.
Various construction products are specified within these drawings. These products shall be used in complete accordance with the product manufacturer’s instructions. Failure to do so may resort in property damage, injury or death.

Warning
Do not substitute products or interchange components from different manufacturers.
Substituted products may not have the same load carrying capacity or functionality as those specified. Product components from different manufacturers may not be compatible, causing product malfunction and/or a reduction in the products load carrying capacity. Either case may result in an unexpected failure of the product, resulting in possible property damage, injury or death.

Warning
Do not use damaged or worn products and equipment.
All construction products, equipment, hardware and braces shall be inspected for damage and wear prior to use. Damaged or worn items shall not be used as malfunction and/or reduced load carrying capacity could result in unexpected failure causing possible property damage, injury, or death.

Warning
Stay clear of tilt-up panels during erection.
Do not get beneath panels. Do not ride or climb on panels. Stay clear of panel fall zones. Failure to do so may result in property damage, injury, or death.

Warning
Do not alter rigging, reinforcing steel or strongbacks.
Altering the rigging can change the applied lift insert loads, panel stresses and overall behavior of the panel during erection. Altering or omitting reinforcing steel or strongbacks can cause cracking or complete panel collapse during erection. Both can lead to property damage, severe injury or death.

Warning
Follow all OSHA Standards and other applicable safety standards.
Pay particular attention to OSHA 1926(b)(1) through (2), 1926.21(b)(2) and 1926.704; and PCI Erection Safety Manual (MNL 132). Failure to do so may result in property damage. Injury, or death.

Warning
Do not deviate from the information shown on the drawings without notifying and obtaining approval from Surebuilt Engineering Services.

DANGER
Falling Panels, bracing or hardware can cause property damage, severe injury or death.

Read all instructions and notes contained within this tilt-up construction drawings booklet. All information should be clearly understood by all job site personnel involved in the construction and erection process prior to proceeding with construction. If anyone is unclear as to the intent of the drawings or notes, contact Surebuilt Engineering Services for clarification.

Failure to follow all instructions and warnings contained herein, may result in exposure of workers and other personnel in the area of the job site to unsafe conditions or hazards that can cause property damage, severe injury or death.

Call 708-493-9569
www.surebuilt-usa.com

PAGE 50
========================================================================

Line Card

Bar Support
Slab Bolster
Slab Bolster Upper
Individual High Chair
Continuous High Chair
Continuous High Chair Upper
Beam Bolster
Bridge Deck Forming
Bridge Overhang Bracket
HD Bridge Overhang Bracket
Curing Blankets
Exterior Hangers
Exterior Half Hangers
Interior Hangers
Interior Half Hanger
Adjustable Joist Hanger
Coil Rod
1/2”, 3/4”, 1” Coil Rod
1-1/4” Coil Rod
15mm, 20mm Coil Rod
Coil Ties
1/2”, 3/4”, 1” Coil Ties
1-1/4” Coil Ties
Concrete Hoppers
Hoppers
Elephant Trunk
Tremie Pipe
Steel Collar
Floor Systems
Dowel Basket
Taper Dowel
Steel Edge Nosing
VaporStop & Tape
Form Liners
HIPS – Single Use
ABS – Up to 10 Uses
PE – Up to 40 – 50 Uses
PPE – Up to 100+ Uses
Form Ties
HD Loop Ties
HD Gang Loop Ties

Form Ties
X-Flat Ties
Base Ties
Aluminum Form Ties
Heavy Forming
SOLO Clamp Form 1500PSF
Sure Beam
Articulated Waler
Steel Circular Column Form
Taper Ties
She-Bolts
Inner Units
Euro Taper Ties
Euro She-Bolts
Flat Washers
GFRP Reinforcement Bar
#2-#11 Reinforcement Bar
Stay-in-Place Forms
EcoForm
Metal Rib
Modular Braces
Type 6-5/8”
Type 8-5/8”
Pipe Braces
Plywood Forming
Coil Ties
Pencil Rod and Clamps
Self-Centering Ties
Snap Ties
Precast
Anchor Rail HD
Coil Inserts
Column Wall Edge Connector
Ferrule Inserts
Helical Ground Anchors
Ring and Cable Lifters
Slant Anchor
Straight Leg Anchor
Wall Base Connector
Wire / FRP Truss
Rebar Safety Caps

Rebar Splicing
Groutec
Unitec
Self-Riser System
Shoring
Cross Braces
Frames
Post Shores
Screw Jacks
Snap Ties
SPAN-X Beams
Staybox Rebar Splicing
Steel Stakes
3/4” Stakes
7/8” Stakes
Stud Rail DSA & DSAR
Stud Rail
Thermal Break
SurePly™ Handset Forming
Panels and Fillers
Hardware
HD Loop Ties
X-Flat Ties
Birch Plywood
Renovation
Tilt-Up
Bolted Panel Connections
Brace Inserts
Helical Ground Anchors
Lifting Hardware
ParaCleat
ProLift Inserts
Slant Anchor
SureLift (SL) Inserts
Edge Form Brackets
Construction Adhesive
FRP Truss / Connectors
XL Lift Inserts
Walers
Butt Plate
Double Channel

SureBuilt
Concrete Forms & Accessories

2525 Armitage Ave
Melrose Park, IL 60160
708-493-9569
www.surebuilt-usa.com

MADE IN USA
09/26