Panel Base Connector – P

Panel Base Connector – P*

Eliminate misaligned embed plates and field welding by

bolting panels directly to the foundation

The Panel Base Connector-P is easy to position

and fasten at the bottom edge of the form. It can be

placed in either a face-up or face-down orientation

depending on the forming and handling preference.

The high-strength, purpose designed drill-in 3/4”x10”

screw anchor provides an immediate and secure

connection when tightened. There is no grout set-up

or wait time.

The connection is centered in the concrete panel,

minimizing moment and eccentric forces in the

design, and resisting in-plane tension and out-of-

plane shear forces.

Foam thickness can be increased to center PBC-P in wall.

The connection provides a nominal capacity in

excess of 10 Kips for tension, meeting the applicable

ACI requirements.

The relatively small access area is easy to grout,

providing complete embedment and encapsulation

for corrosion protection.

Panel Base Connector Kit

Part No. Description

SBPBC10-P 10” Panel Base Connector – P Kit w/ 3/4” x 10” Screw Anchor

SBPBC12-P 10” Panel Base Connector – P Kit w/ 3/4” x 12” Screw Anchor

* 12” Screw Anchor available if spacing between bottom of panel and footing is more than 2”.

Meets ACI integrity requirements of ACI-318 -11

16.5.1.3(b) ACI318-14 16.2.4.3(b), ACI-318-19

16.2.4.3 (b), and ACI 551.2R-15 Chapter 8.

Note: 7” Screw Anchor

engagement required

* Patent No.: U.S. 11,891,790

2525 Armitage Ave

Melrose Park, IL 60160

708-493-9569

www.surebuilt-usa.com

09/26Basic Installation

1. Position and fasten the Panel Base Connector-P to the desired

location(s) in the bottom edge of panel formwork using the holes

provided or hold up for upside wall projection.

2. Cast, lift, handle and erect the completed panel on the concrete

footing or foundation as typical.

3. Remove the foam cover from the face of Panel Base Connector-P.

4. Through the opening of the Panel Base Connector-P, drill a

minimum 3/4” x 7” hole in foundation, using a 3/4” bit, into the

footing or foundation.

5. Clean the concrete dust from each hole.

6. Place the 3/4” x 10” screw anchor though the Panel Base

Connector-P into the footing or foundation.

7. Torque anchor into the footing or foundation with a maximum of

150 ft.-lbs. Do not over-torque anchor.

8. Grouting cavity or patching face of panel is not required and is

optional.

10” PBC-P

Position and fasten

the connector along

the bottom edge of the

panel formwork.

Position and chair

the connector along

the top edge of the

panel formwork.

Drill a 3/4” x 7” hole, using

a 3/4” x 24” bit, through the

opening of the connector into

the footing or foundation.

Place a 3/4” x 10” screw

anchor though the connector

and footing or foundation,

then torque to 150 ft-lbs.

Grouting cavity or patching

face of panel is not required

and is optional.Installation Detail

EDGE DISTANCES FOR ANCHORS TO BE

PER SPECIFICATIONS OF THE ANCHOR

MANUFACTURER. RECOMMENDED

MINIMUM EDGE DISTANCE IS 9″.

WALL PANEL

X”

7″ MIN.

CAST IN PLACE FOUNDATION

APPROX. DIMENSION FOR THE DEPTH

OF THE ANCHORAGE ASSUMING A 10″

LONG SCREW ANCHOR & A 1″-2″ GROUT

JOINT. VERIFY FOOTING DEPTH WITH

THE STRUCTURAL DRAWINGS. MINIMUM

DISTANCE TO BOTTOM OF FOOTING TO

BE PER SPECIFICATIONS OF THE

ANCHOR MANUFACTURER.

4″

NON-SHRINK, NON-METALLIC GROUT

4″

COORDINATE WITH EOR/GC TO HAVE REINFORCEMENT

ONLY IN CORNERS, OR TO SHIFT ANY INTERMEDIATE

REINFORCEMENT OUT OF THE ANCHORAGE ZONE.

DIMENSIONS SHOWN ARE MINIMUM DISTANCE TO SHIFT

OVER THE REINFORCEMENT.

Repair Concept

PBC-P REPAIR CONCEPT

IN CASE 3 4“Ø x 10” CONCRETE SCREW

ANCHOR HITS REBAR.

2

1 2

3

4

1. PLACE 1/2″ x 3″ x 15″ STRIP UNDER PANEL.

2. WELD STRIP (1/4″ x 3″) TO BOTTOM OF PBC-P.

(3.7 KIPS/INCH)

3. DRILL (2) 3/4″Ø HOLES IN FOOTING, 5″ DEEP.

4. PLACE 3/4″Ø x 6″ CONCRETE SCREWS IN FOOTING.

NOTE: CLEAN/PREPARE AREA FOR WELDING.

COVER WELD AREA FOR CORROSION AFTER WELDING.

DISCLAIMER:

The repair information provided is for general guidance only & is not intended as a substitute for

professional engineering review or approval. The suitability, effectiveness & safety of any repair

should be evaluated & verified by a qualified engineer based on the specific project conditions,

structural requirements & applicable codes & standards. The responsibility for ensuring the

adequacy of the repair remains with the project engineer & other relevant professionals. The

manufacturer & distributor assume no liability for improper use, application or reliance on this

information.

The following repair concept has been provided to assist in the repair of a PBC-P connection if the

hole cannot be drilled to appropriate depth or if the bolt in not able to be fully installed or reach the

recommended torque levels.

Capacity of repair strength to be determined by project engineer based on foundation conditions &

criteria.

File Type: pdf
Categories: Data Sheets