Emergency Lift Plate

Emergency Lift Plate

Precautionary method for lifting a tilt-up panel when

inserts are improperly located or unusable

The Emergency Lift Plate is designed for situations when the

original insert is improperly located or unusable. The plate is

attached to the tilt-up panel using Titen HD Anchors 3/4”x6”

(recommended) or equivalent. Refer to manufacturer instructions

and load chart for proper anchor installation and capacity.

The Emergency Lift Plate should be installed over the original

insert location or in alternate position designated by an

experienced tilt-up professional. If uncertain about the location,

contact the lift/brace engineer for further recommendations.

Always be certain the Emergency Lift Plate is aligned with crane

rigging cables.

The Emergency Lift Plate has a maximum safe working load

(SWL) of 22,000 lbs. (at 5:1 safety factor) and should never be

used in excess of that capacity.

When drilling holes for anchors, be careful not to inadvertently

damage structural rebar in the tilt-up panel. Only the Engineer

of Record (EOR) can approve deviations in the rebar design

or integrity. Contact the lift/brace engineer if reinforcing or

reconfiguration is needed for lifting purposes.

* Safe Working Load (SWL) based on 5:1 safety factor.

Warning:

1. Concrete must have minimum 3,000 psi compressive strength.

2. Do not use the Titen HD Anchor in panels thinner than 7”.

3. Edge distance must be minimum of 12” to center of holes.

4. Do not reuse Titen HD Anchor bolts.

Emergency Lifting Plate

Fasten plate with

Titen HD Anchor 3/4” X 6”

Safe working load is 6,845 lbs

(2:1 safety factor)

Emergency Lifting Plate

Part No.

Description

SWL*

SBELP

Emergency Lifting Plate 12”x12”

22,000 lbs

2525 Armitage Ave

Melrose Park, IL 60160

708-493-9569

www.surebuilt-usa.com

03/26A screw anchor is used to fasten the Emergency Lifting Plate to the tilt-up

panel. The load-rated, Titen-brand screw anchor has a flanged head and

unthreaded shaft, allowing for the thickness of the plate. Other brands are

acceptable, but the bolts must be 3/4” diameter and the capacities must

be confirmed with the manufacturer before installation.

Titen HD Screw Anchor

Part No. Description Slab SWL*

SBTHD346G Titen HD Anchor 3/4”x6” Galv 6” 7,500 lbs

SBTHD347G Titen HD Anchor 3/4”x7” Galv 7” 9,000 lbs

* Safe Working Load (SWL) using 2:1 safety factor in 3,000 psi concrete.

Drill hole Clean hole Torque bolt Check fit

Installation:

1. Drill holes at 90O angle to the surface with a 3/4” carbide-tipped bit.

2. Drill a minimum of 5-3/4” deep for 6” anchor.

3. Clean the drilled holes with compressed air or blow-out bulb.

4. Only use new Anchors with clean and undamaged threads.

5. Place Brace Shoe over the hole and position anchor.

6. Securely tighten anchor using a 3/4” impact wrench to 100 ft-lbs.

7. Use 3/4” F436 Structural Washer where needed.

File Type: pdf
Categories: Data Sheets