Emergency Lift Plate
Emergency Lift Plate
Precautionary method for lifting a tilt-up panel when
inserts are improperly located or unusable
The Emergency Lift Plate is designed for situations when the
original insert is improperly located or unusable. The plate is
attached to the tilt-up panel using Titen HD Anchors 3/4”x6”
(recommended) or equivalent. Refer to manufacturer instructions
and load chart for proper anchor installation and capacity.
The Emergency Lift Plate should be installed over the original
insert location or in alternate position designated by an
experienced tilt-up professional. If uncertain about the location,
contact the lift/brace engineer for further recommendations.
Always be certain the Emergency Lift Plate is aligned with crane
rigging cables.
The Emergency Lift Plate has a maximum safe working load
(SWL) of 22,000 lbs. (at 5:1 safety factor) and should never be
used in excess of that capacity.
When drilling holes for anchors, be careful not to inadvertently
damage structural rebar in the tilt-up panel. Only the Engineer
of Record (EOR) can approve deviations in the rebar design
or integrity. Contact the lift/brace engineer if reinforcing or
reconfiguration is needed for lifting purposes.
* Safe Working Load (SWL) based on 5:1 safety factor.
Warning:
1. Concrete must have minimum 3,000 psi compressive strength.
2. Do not use the Titen HD Anchor in panels thinner than 7”.
3. Edge distance must be minimum of 12” to center of holes.
4. Do not reuse Titen HD Anchor bolts.
Emergency Lifting Plate
Fasten plate with
Titen HD Anchor 3/4” X 6”
Safe working load is 6,845 lbs
(2:1 safety factor)
|
Emergency Lifting Plate |
||
|
Part No. |
Description |
SWL* |
|
SBELP |
Emergency Lifting Plate 12”x12” |
22,000 lbs |
2525 Armitage Ave
Melrose Park, IL 60160
708-493-9569
www.surebuilt-usa.com
03/26A screw anchor is used to fasten the Emergency Lifting Plate to the tilt-up
panel. The load-rated, Titen-brand screw anchor has a flanged head and
unthreaded shaft, allowing for the thickness of the plate. Other brands are
acceptable, but the bolts must be 3/4” diameter and the capacities must
be confirmed with the manufacturer before installation.
Titen HD Screw Anchor
Part No. Description Slab SWL*
SBTHD346G Titen HD Anchor 3/4”x6” Galv 6” 7,500 lbs
SBTHD347G Titen HD Anchor 3/4”x7” Galv 7” 9,000 lbs
* Safe Working Load (SWL) using 2:1 safety factor in 3,000 psi concrete.
Drill hole Clean hole Torque bolt Check fit
Installation:
1. Drill holes at 90O angle to the surface with a 3/4” carbide-tipped bit.
2. Drill a minimum of 5-3/4” deep for 6” anchor.
3. Clean the drilled holes with compressed air or blow-out bulb.
4. Only use new Anchors with clean and undamaged threads.
5. Place Brace Shoe over the hole and position anchor.
6. Securely tighten anchor using a 3/4” impact wrench to 100 ft-lbs.
7. Use 3/4” F436 Structural Washer where needed.