Wall Base Connector Data Sheet
Wall Base Connector
Quickly position and bolt pre-engineered precast
concrete panels in place
The pre-engineered assembly provides a moment
connection at wall-to-base and wall-to-wall locations.
This bolted connection eliminates the need for
temporary bracing and panel welding, saving time.
The Wall Base Connector is designed for common
anchor bolt sizes. An integrated box-out provides
access at each bolt location. The plate and rebar are
matched to load specifications.
Each Wall Base Connector includes a steel plate
(Grade 50) and rebar (A706) welded in accordance
with American Welding Society (AWS) standards. An
optional galvanized finish is also available.
Site construction
happens quickly
when wall panels
are immediately
positioned and
bolted into place.
Once the wall panels have been positioned and
bolted, the base must be grouted to provide bearing
for the engineered load.
|
Wall Base Connector* |
||||
|
Type |
SBWBC34 |
SBWBC1 |
SBWBC114 |
SBWBC112 |
|
Base plate |
3-1/2”x3-1/2” |
4”x4” |
5”x5” |
7”x7” |
|
Plate thickness |
3/4” |
1-1/4” |
1-3/4” |
2” |
|
Hole size |
1-1/8” |
1-3/8” |
1-3/4” |
2” |
|
Rebar size/length |
#5 x33” |
#6 x42” |
#8 x52” |
#9 x70” |
|
Shear (lbs) |
9,500 |
17,000 |
27,000 |
47,000 |
|
Tension** (lbs) |
19,000 |
34,000 |
54,000 |
95,000 |
|
Anchor bolt size |
3/4”x16” |
1”x17” |
1-1/4”x20” |
1-1/2”x30” |
|
Anchor bolt F1554 |
Grade 55 |
Grade 55 |
Grade 55 |
Grade 90 |
* Moment connection must be approved by the Engineer of Record (EOR).
**
Tension based on 6,000 psi concrete.
2525 Armitage Ave
Melrose Park, IL 60160
708-493-9569
www.surebuilt-usa.com