HD Sandwich Panel Erection Anchor Data Sheet

Heavy Duty Sandwich Panel Erection Anchor
By delivering an even load distribution to both sides of a sandwich panel, the HD Sandwich Panel Erection Anchor transfers the highest loads on panel edge without shear bars.
The anchor is easy to install and the design absorbs shear loads without spalling concrete. Additional shear reinforcement can be added if necessary to increase the shear capacity.
Given full embedment, reinforcement, and a minimum compressive strength of 4,500 psi, the 10T Sandwich Panel Erection Anchor will achieve a pullout strength equal to the ultimate strength when reinforced with two #6 x 3’-6” long bent bars.
* Based on 4:1 Safety Factor
SBDFSPEA346G
Drop-Forged HD Sandwich Panel Erection Anchor
Part No.
Tons
10T
Clutch ID
Dimensions
8-10T
L
6”
A
3-3/4”
B
2-29/32”
C
3/4”
D
4”
Heavy Duty Sandwich Panel Erection Anchor for 8” Thick Panels (3”x2”x3”)
Anchor Tonnage
Tension
Shear-Parallel to Thickness 2.66:1
Shear-Parallel to Thickness 4:1
Shear-Perpendicular to Thickness 4:1 SF
tons
lb
lb
lb
lb
10T
22,000
5,700
4,200
10,500
* Based on 4:1 Safety Factor with reinforcement bar through anchor (1.)
** Additional shear bar can be placed on side of anchor to increase shear load. Shear bar #5 min 24” long.
Heavy Duty Sandwich Panel Erection Anchor for 10” Thick Panels (4”x3”x3”)
Anchor Tonnage
Tension
Shear-Parallel to Thickness 2.66:1
Shear-Parallel to Thickness 4:1
Shear-Perpendicular to Thickness 4:1 SF
tons
lb
lb
lb
lb
10T
22,000
7,200
4,800
10,500
* Based on 4:1 Safety Factor with reinforcement bar through anchor (1.)
** Additional shear bar can be placed on side of anchor to increase shear load. Shear bar #5 min 24” long. (2.) (1.) and (2.) shear bar 10 ton #6 x 6”, tension bar 10 ton #6 x 3’6”.
840 South 25th Ave Bellwood, IL 60104 708-493-9569 www.surebuilt-usa.com
04/23

Drop-Forged Heavy Duty Sandwich Panel Erection Anchor
Part No.
Tons
Clutch ID
L
A
SL
SW
T
IT
SBDFSPEA347G
10T
8-10T
7”
4-13/16”
1-13/16”
1-1/8”
3/4”
3”
SBDFSPEA348G
10T
8-10T
8”
5”
1-13/16”
1-1/8”
3/4”
4”
Part No.
Drop-Forged HD Sandwich Panel Erection Anchor Anchor Capacity in Concrete
Tons
Concrete PSI (lbs)
*Shear-Parallel to Thickness 2.66:1 SF (lbs)
*Shear-Parallel to Thickness 4:1 SF (lbs)
*Shear- Perpendicular to Thickness 4:1 SF (lbs)
**Tension 4:1 SF (lbs)
SBDFSPEA347G
10T
4,500
7,000
4,500
10,500
22,000
SBDFSPEA348G
10T
4,500
6,500
4,200
9,200
22,000
* Shear based on Grade 60 rebar #6 x 6”
** Tension based on Grade 60 rebar #6 x 49” at 30 degree bend
Minimum cover on Tension Bar is 5/8”

File Type: pdf
Categories: Data Sheets