Bolted Connection

Bolted Connection

Bolted, inline connection for concrete wall panels

The Bolted Connection was specifically designed

and engineered to eliminate welding operations

for panel-to-panel connections.This simplified

method allows for to installation by crew members

already working onsite. This reduces costs and

time consuming inspection procedures required

with weld plates and field welding. Installation can

be completed when weather is not suitable for

welding.

Bolted Connections are adjustable which allows

greater flexibility when there are inconsistencies

in foundation elevations. Only a torque wrench is

required for installation.

* Minimum wall panel thickness for SBBPTPC is 4”.

CONCRETE SHOWN FOR REFERENCE ONLY

** All materials are HDG

Bolted Connection

*Bolted Connection

Part No.

Description

Components

Qty

SBBPTPC 3

Anchor Rail HD

2

Serrated Hex Flange Nut

2

**Bolted Connection

2

M16 T-Bolt 8.8 1

2

Square Washers 3”x3”x3/8”

2

Panel-to-Panel Connection Plate 1

B

.38

0 4.00 .50

3 SQ.

2525 Armitage Ave

Melrose Park, IL 60160

708-493-9569

www.surebuilt-usa.com

02/26

ITEM

1

QTY

2

PART NUMBER

DESCRIPTION

Anchor Rail 5/8″

-11 x 2″ T-Bolt4

3

2

Structural Washer

2

1

3.00

.38

1.50

n.80

1

REV:

SIZE:

B

SCALE:

N.T.S.

MATERIAL:

GRADE 50 STEEL

FINISH: WEIGHT:

GALVANIZED SEE DWG.

LBS

R.33

3

2

.412

L 60104

) 493-9601

Panel-to-Panel Connection Plate

4

3

14.25

1.375 2.75

2.75

1.375

.50

B B

7.50 LBS.

2.00

3.00

4.00

n.80

A A

1.50

4.00

4.00

Round washers available upon request.

.75 WALL JOINT

3

2

T-Bolt

T-Bolt and Serrated Flange Nut

n.80

A A

Part No. Description 1.50

Size

DIMENSIONS ARE IN INCHES

REV:

MATERIAL:

TITLE:

DATE:

SBM16TBOLT88 UNLESS OTHERWISE SPECIFIED

TOLERANCE:

T-Bolt 8.8 1/2″ x 4″ x 14-1/4″ PLATE w/ (2) SLOTS and

GRADE 50 STEEL

FRACTIONS: ±1/32″

.412

M16

10-22-2025

SIZE:

3/8″ x 3″ x 3″ WASHER

DRAWN:

DDM

DECIMALS:

NOTE: THE INFORMATION CONTAINED

0.0………..±0.063

B

PART NO:

CHECKED:

IN THIS DRAWING IS THE SOLE

0.00………±0.031

PROPERTY OF SUREBUILT COMPANY.

2525 ARMITAGE AVE., MELROSE PARK, IL 60160

4

PHONE: (708) 493-9569 – FAX: (708) 493-9601

SBSHFN ANY REPRODUCTION IN PART OR AS

0.000…….±0.010

SCALE:

FINISH: WEIGHT:

3

A WHOLE WITHOUT THE WRITTEN

ANGLES: ±1°

2

GALVANIZED SEE DWG.

DWG. NO: PERMISSION OF SUREBUILT

UNLESS OTHERWISE SPECIFIED

COMPANY IS PROHIBITED.

Serrated Hex Flange Nut 1

N.T.S.

LBS

M16

SHEET:

APPROVED:

1

OF

1

4

3

2

1

NOTE: THE INFORMATION CONTAINED

IN THIS DRAWING IS THE SOLE

PROPERTY OF SUREBUILT COMPANY.

2525 ARMITAGE AVE., MELROSE PARK, IL 60160 ANY REPRODUCTION IN PART OR AS

B B

Serrated Hex Flange Nut

A WHOLE WITHOUT THE WRITTEN

PHONE: (708) 493-9569 – FAX: (708) 493-9601

PERMISSION OF SUREBUILT

COMPANY IS PROHIBITED.

4

.125

.060

DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

TOLERANCE:

FRACTIONS: ±1/32″

DECIMALS:

0.0………..±0.063

0.00………±0.031

0.000…….±0.010

ANGLES: ±1°

UNLESS OTHERWISE SPECIFIED

3

4

5/8-11 UNC – 2A

n.300

B

*The serrated flange resists loosening due to vibration.

A A

Anchor Rail HD

2525 ARMITAGE AVE., MELROSE PARK, IL 60160

PHONE: (708) 493-9569 – FAX: (708) 493-9601

4

DIMENSIONS ARE IN INCHES

REV:

MATERIAL:

TITLE:

UNLESS OTHERWISE SPECIFIED

TOLERANCE:

GRADE 8 STEEL

FRACTIONS: ±1/32″

SIZE:

DECIMALS:

NOTE: THE INFORMATION CONTAINED

0.0………..±0.063

B

PART NO:

IN THIS DRAWING IS THE SOLE

0.00………±0.031

PROPERTY OF SUREBUILT COMPANY.

ANY REPRODUCTION IN PART OR AS

0.000…….±0.010

SCALE:

FINISH: WEIGHT:

A WHOLE WITHOUT THE WRITTEN

ANGLES: ±1°

PERMISSION OF SUREBUILT

N.T.S.

UNLESS OTHERWISE SPECIFIED .11

LBS

COMPANY IS PROHIBITED.

3

2

DATE:

12-17-2025

M16 SERRATED FLANGE HEX NUT DIN 6923

DRAWN:

DDM

CHECKED:

DWG. NO: SHEET:

APPROVED:

1

OF

1

1

.750

n.300

A

.500

.625

R.33

DIMENSIONS ARE IN INCHES

REV:

MATERIAL:

TITLE:

UNLESS OTHERWISE SPECIFIED

*Insert the T-Bolt into the Anchor Rail HD

TOLERANCE:

ANCHOR RAIL 5/8″

-11 x 2″ T-Bolt

FRACTIONS: ±1/32″

SIZE:

DECIMALS:

NOTE: THE INFORMATION CONTAINED

0.0………..±0.063

B

PART NO:

IN THIS DRAWING IS THE SOLE

0.00………±0.031

840 S. 25TH AVE. BELLWOOD, IL 60104 channel slot. After a 90o turn clockwise the

PROPERTY OF SUREBUILT COMPANY.

ANY REPRODUCTION IN PART OR AS

0.000…….±0.010

SCALE:

FINISH: WEIGHT:

A WHOLE WITHOUT THE WRITTEN

ANGLES: ±1°

DWG. NO: PHONE: (708) 493-9569 – FAX: (708) 493-9601

PERMISSION OF SUREBUILT

N.T.S.

UNLESS OTHERWISE SPECIFIED .37

A

LBS

COMPANY IS PROHIBITED.

4

3

T-Bolt locks into position.

2

Part No. DIMENSIONS ARE IN INCHES

A B REV:

MATERIAL:

C L

UNLESS OTHERWISE SPECIFIED

TOLERANCE:

SBARHD8G FRACTIONS: ±1/32″

2” 1-1/4” SIZE:

5-1/4” 8”

DECIMALS:

NOTE: THE INFORMATION CONTAINED

0.0………..±0.063

B

IN THIS DRAWING IS THE SOLE

0.00………±0.031

PROPERTY OF SUREBUILT COMPANY.

ANY REPRODUCTION IN PART OR AS

0.000…….±0.010

SCALE:

FINISH: WEIGHT:

A WHOLE WITHOUT THE WRITTEN

PERMISSION OF SUREBUILT

Anchor Rail HD – Properties

ANGLES: ±1°

N.T.S.

UNLESS OTHERWISE SPECIFIED .37

LBS

COMPANY IS PROHIBITED.

Load 3

Capacity SWL*

Pull-Out 11,250 lbs 3,750 lbs

PART NO:

DATE:

*SureBuilt T-Bolts only work with SureBuilt

10-24-2025

ANCHOR RAIL 5/8″

Anchor Rail HD.

-11 x 2″ T-Bolt

DRAWN:

DDM

CHECKED:

DWG. NO: SHEET:

APPROVED:

2

1

OF

1

1

Shear 5,500 lbs 1,833 lbs

*

**

Safe Working Load based on a safety factor of 3:1 in minimum 3,000 psi concrete.

Additional reinforcement required when rail placed close to edges or openings.

TITLE:

1/2″ x 4″ x 14-1/4″ PLATE w/ (2)

B

3/8″ x 3″ x 3″ WASHER

PART NO:

DWG. NO:

2

1

.825

.125

.060

R.33

.140

5/8-11 UNC – 2A

n.300

1.50

1.50

.750

n.300

.140

.500

.625

R.33

2.000

2.000

Anchor Rail HD – Dimensions

SHEET:

1

OF

1

TITLE:4

3

Bolted Connection

.75 WALL JOINT

CONCRETE SHOWN FOR REFERENCE ONLY

B

.38

4.00 4.00

.50

7.88

4

3 SQ.

14.25

A

2525 ARMITAGE AVE., MELROSE PARK, IL 60160 PHONE: (708) 493-9569 – FAX: (708) 493-9601

4

NOTE: THE INFORMATION CONTAINED

IN THIS DRAWING IS THE SOLE

PROPERTY OF SUREBUILT COMPANY.

ANY REPRODUCTION IN PART OR AS

A WHOLE WITHOUT THE WRITTEN

PERMISSION OF SUREBUILT

COMPANY IS PROHIBITED.

DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

REV:

MATERIAL:

TOLERANCE:

FRACTIONS: ±1/32″

DECIMALS:

0.0………..±0.063

0.00………±0.031

0.000…….±0.010

ANGLES: ±1°

SEE PARTS LIST

SIZE:

B

SCALE:

FINISH: WEIGHT:

N.T.S.

UNLESS OTHERWISE SPECIFIED LBS

3

Engineer of Record to specify number of connections per joint and maximum connection spacing.

Bolted Connection Notes

1. Out-of-plane loads are assumed to act on one side of corner at any point in time.

2. Anchor Channel allows for +/- 2” up/down tolerance.

3. Each side of bracket allows for +/- 1” left/right tolerance.

4. T-Bolt must be installed between the end anchors.

5. Place plate and washer and tighten nut to 52 lbf-ft. Exceeding capacity may damage the connections.

6. After tightening the nut, check whether the T-Bolt for correct installation. If the T-Bolt head is not perpendicular to the

channel axis, the T-Bolt must be completely loosed, re-aligned, re-tightened, and then re-checked for correct installation.

2

ITEM

QTY

1

2

2

1

3

2

4

2

5

2

6

2

TITLE:

PANEL T

PART NO:

DWG. NO:

2

File Type: pdf
Categories: Data Sheets