Square Dowel
Square Dowel
An engineered load transfer system for horizontal
movement in concrete slabs
The size and rectangular-shape of the Square Dowel
provides concrete joint stability, load transfer and
smooth slab-to-slab transition, without restraining
floor movement.
The plastic sleeve is nailed to lumber edge forms
before concrete placement and the steel plate
slides into the sleeve after forms are removed in
preparation for the adjoining slab.
The Square Dowel simplifies dowel installation,
eliminates slab edge drilling and reduces labor costs
for all types of ground level concrete slabs, including
floors, flatwork and pavement.
The plastic sleeve allows movement and the steel
plate provides maximum bearing, bending and
punching resistance, without the risk of slab interlock
common with other methods.
Rigid, high-density plastic sleeve quickly attaches to
edge forms and minimizes related labor costs.
A properly installed Square Dowel is recommended
for joints up to 0.20” wide and is suitable for all types
of ground level concrete slabs, such as jointed floors,
flatwork and pavement.
A Square Dowel installation conforms to ACI 302.1R
Guide for Concrete Floor and Slab Construction and
ACI 360 Design of Slabs-on-Ground.
|
Square Dowel Set (One Sleeve and One Plate) |
|||
|
Part No. |
Description |
Slab |
Spacing* |
|
SBSD14SL |
SB Square Dowel 1/4” Sleeve Only (Blue) |
5” to 6” |
18” |
|
SBSD14PL |
SB Square Dowel 1/4” Plate Only 1/4” x 4” x 6” |
||
|
SBSD38SL |
SB Square Dowel 3/8” Sleeve Only (Red) |
7” to 8” |
18” |
|
SBSD38PL |
SB Square Dowel 3/8” Plate Only 3/8” x 4” x 6” |
||
* Spacing shown based on ACI 360 Design of Slabs-on-Ground.
2525 Armitage Ave
Melrose Park, IL 60160
708-493-9569
www.surebuilt-usa.com
03/261. Square Dowel Installation
Mark a horizontal line on formwork for the half
slab thickness. Mark a vertical line for the center-
to-center spacing of the dowel sleeve. Fasten
all dowel sleeves securely at each marked
location. Position and tie any remaining slab
reinforcement.
2. Place concrete normally, completely surrounding
each dowel sleeve location. All dowel sleeves
require adequate vibrator compaction to eliminate
any air entrapment under the sleeve. Do not
strike/damage dowel sleeves with the vibrator.
3. When concrete reaches sufficient strength,
adjoining slab base can be levelled and
compacted. Insert the steel plate dowels into the
sleeves by puncturing the protective cover strips.
The plate dowels should be completely inserted
into the sleeves.
4. Position and tie any remaining slab reinforcement.
The adjoining slab can now be placed against
the face of the first and the exposed steel plate
dowels. Place concrete normally, completely
surrounding each plate dowel location.